PORTABLE DEVICE FOR PESTICIDE TOXICITY ANALYSIS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F03%3APU36335" target="_blank" >RIV/00216305:26220/03:PU36335 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
PORTABLE DEVICE FOR PESTICIDE TOXICITY ANALYSIS
Popis výsledku v původním jazyce
Fast detection of pesticide toxicity in field conditions is not fully solved yet. The new device for field measurement of organophosporous pesticides toxicity is described. The detection is based on the inhibition of acetylcholinesterase. The enzyme acetylcholinesterase is immobilized on a miniature electrochemical detector made by thick film technology forming together a biosensor. The dimensions of biosensor are 7,35 x 25,4 mm. The biosensor is placed in flow chamber which assures the reproducible hyddrodynamic conditions near of active surface of the sensor. The analyzed sample is detected in the flow of supporting buffer. The biosensor detects the integral sample toxicity. It is destinated for detection of traces of pesticides in washout from leaves for direct measurment in rivers, ponds, vaste waters and drinking water sources. The preconcentration of sample is possible. The detection limit varies in wide range depending on the toxicity of pesticide.
Název v anglickém jazyce
PORTABLE DEVICE FOR PESTICIDE TOXICITY ANALYSIS
Popis výsledku anglicky
Fast detection of pesticide toxicity in field conditions is not fully solved yet. The new device for field measurement of organophosporous pesticides toxicity is described. The detection is based on the inhibition of acetylcholinesterase. The enzyme acetylcholinesterase is immobilized on a miniature electrochemical detector made by thick film technology forming together a biosensor. The dimensions of biosensor are 7,35 x 25,4 mm. The biosensor is placed in flow chamber which assures the reproducible hyddrodynamic conditions near of active surface of the sensor. The analyzed sample is detected in the flow of supporting buffer. The biosensor detects the integral sample toxicity. It is destinated for detection of traces of pesticides in washout from leaves for direct measurment in rivers, ponds, vaste waters and drinking water sources. The preconcentration of sample is possible. The detection limit varies in wide range depending on the toxicity of pesticide.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/FD-K2%2F53" target="_blank" >FD-K2/53: Výzkum nových metod přístrojové analýzy toxicity pro integrální měření toxicity v potravinářském průmyslu a jejich ověření na prototypu analyzátoru toxicity pesticidů.</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2003
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of 9th conference and competition Student EEICT 2003, Volume 3
ISBN
80-214-2379-x
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
440-444
Název nakladatele
Vysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních technologií
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
24. 4. 2003
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—