Ripple Control Signal Using For Earth Fault Location In MV Networks
Popis výsledku v původním jazyce
At present, digital protections using the admittance principle are able to identify quite reliably a single phase-to-ground connection and to determine the affected feeder. Still, the location of the fault presents a task yet to be solved. The main problem of a fault location consists is a low value of the fault current during a single phase-to-ground fault in com-pensated networks. This work started of an experiment performed in the second half of 2001. The experiment explored a possibility of the idenntification of a fault location in a circular network by means of ripple-control signal. The work deals with a novel method for a fault location that is able to determine the distance of a fault in a radial network (without a pos-sibility of a circular interconnection) using only values measured in a switching station. The principle of this method was published in 2000 [1]. It presents the application of the method in a real distribution network and the evaluation of the re-sults of this
Název v anglickém jazyce
Ripple Control Signal Using For Earth Fault Location In MV Networks
Popis výsledku anglicky
At present, digital protections using the admittance principle are able to identify quite reliably a single phase-to-ground connection and to determine the affected feeder. Still, the location of the fault presents a task yet to be solved. The main problem of a fault location consists is a low value of the fault current during a single phase-to-ground fault in com-pensated networks. This work started of an experiment performed in the second half of 2001. The experiment explored a possibility of the idenntification of a fault location in a circular network by means of ripple-control signal. The work deals with a novel method for a fault location that is able to determine the distance of a fault in a radial network (without a pos-sibility of a circular interconnection) using only values measured in a switching station. The principle of this method was published in 2000 [1]. It presents the application of the method in a real distribution network and the evaluation of the re-sults of this
Klasifikace
Druh
Jx - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
KJB2813304: Nové způsoby lokalizace zemních spojení v elektrických sítích vln
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Electrical Engineering
ISSN
1335-3632
e-ISSN
—
Svazek periodika
2005
Číslo periodika v rámci svazku
11-12
Stát vydavatele periodika
SK - Slovenská republika
Počet stran výsledku
9
Strana od-do
313-321
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—
Základní informace
Druh výsledku
Jx - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP
JE - Nejaderná energetika, spotřeba a užití energie
Rok uplatnění
2005