Analýza ultrazvukového signálu spojeného s ultrazvukovou kavitací
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F05%3APU51273" target="_blank" >RIV/00216305:26220/05:PU51273 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analysis of acoustic signal incidental to ultrasonic cavitation
Popis výsledku v původním jazyce
Cavitation phenomenon constitutes inconsiderable hazard in ultrasound diagnostic and therapy that is the reason why early and effective detection is necessary. Cavitation constitutes high risk especially when we use echocontrast agent based on microbubbles. Departure of biophysics in conjunction with departure of physics are try to develops detection cavitation method based on increasing level of cavitation noise in range of low frequencies (about 1 Hz). This method is now provided only in-vitro by uusing model of body fluid with echocontrast agent. It was created flow-through system whose principle is cylindrical chest with diameter 30 mm and length 350 mm. On the first side of chest is ultrasound exciter and on the other side is piezoelectric sensor.To make chest airless, airless container is installed. At first, 250 ml of solution is applied to the chest, after that it is excited for 20 s by ultrasound with frequency 800 kHz and intensity 0 - 2.5 W/cm-2. Ultrasound signal in microb
Název v anglickém jazyce
Analysis of acoustic signal incidental to ultrasonic cavitation
Popis výsledku anglicky
Cavitation phenomenon constitutes inconsiderable hazard in ultrasound diagnostic and therapy that is the reason why early and effective detection is necessary. Cavitation constitutes high risk especially when we use echocontrast agent based on microbubbles. Departure of biophysics in conjunction with departure of physics are try to develops detection cavitation method based on increasing level of cavitation noise in range of low frequencies (about 1 Hz). This method is now provided only in-vitro by uusing model of body fluid with echocontrast agent. It was created flow-through system whose principle is cylindrical chest with diameter 30 mm and length 350 mm. On the first side of chest is ultrasound exciter and on the other side is piezoelectric sensor.To make chest airless, airless container is installed. At first, 250 ml of solution is applied to the chest, after that it is excited for 20 s by ultrasound with frequency 800 kHz and intensity 0 - 2.5 W/cm-2. Ultrasound signal in microb
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BM - Fyzika pevných látek a magnetismus
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA205%2F03%2F0071" target="_blank" >GA205/03/0071: Nelineární ultrazvuková defektoskopie pevných látek</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
EDS 05
ISBN
80-214-2990-9
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
154-159
Název nakladatele
Ing. Zdenek Novotny CSc., Brno, Ondráčkova 105
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
15. 9. 2005
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—