Ultrazvuková útlumová tomografie založená na analýze log-spektra
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F05%3APU52366" target="_blank" >RIV/00216305:26220/05:PU52366 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Ultrasonic Attenuation Tomography Based on Log-Spectrum Analysis
Popis výsledku v původním jazyce
The paper presents a new ultrasonic attenuation imaging method which might be used as a new imaging modality, targeted at breast cancer diagnostics. Two approaches based on ultrasonic imaging are combined together, namely the estimation of ultrasound attenuation coe cients from pulse{echo B{mode imaging data and an ultrasound computer tomography imaging technique. A recently published method for estimation of the ultrasound attenuation coe cient using the log{spectrum analysis is applied to radiofrequenncy signals acquired by an ultrasound computer tomography system to estimate images of the attenuation coe cients. The examined volume (e.g. female breast) is enclosed by several thousand ultrasound transducers. Radiofrequency signals from all transducers using all sending positions are recorded. Compared to the known ultrasound attenuation tomography methods, not only the directly transmitted signal, but also the re ected and scattered signals are processed here, i.e. substantially more
Název v anglickém jazyce
Ultrasonic Attenuation Tomography Based on Log-Spectrum Analysis
Popis výsledku anglicky
The paper presents a new ultrasonic attenuation imaging method which might be used as a new imaging modality, targeted at breast cancer diagnostics. Two approaches based on ultrasonic imaging are combined together, namely the estimation of ultrasound attenuation coe cients from pulse{echo B{mode imaging data and an ultrasound computer tomography imaging technique. A recently published method for estimation of the ultrasound attenuation coe cient using the log{spectrum analysis is applied to radiofrequenncy signals acquired by an ultrasound computer tomography system to estimate images of the attenuation coe cients. The examined volume (e.g. female breast) is enclosed by several thousand ultrasound transducers. Radiofrequency signals from all transducers using all sending positions are recorded. Compared to the known ultrasound attenuation tomography methods, not only the directly transmitted signal, but also the re ected and scattered signals are processed here, i.e. substantially more
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JD - Využití počítačů, robotika a její aplikace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/1M0572" target="_blank" >1M0572: Data, algoritmy, rozhodování</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Medical Imaging 2005, Ultrasonic Imaging and Signal Processing
ISBN
0-8194-5724-8
ISSN
—
e-ISSN
—
Počet stran výsledku
10
Strana od-do
305-314
Název nakladatele
SPIE
Místo vydání
USA
Místo konání akce
San Diego
Datum konání akce
15. 2. 2005
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—