Potenciostat s velkým proudovým rozsahem
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F05%3APU54394" target="_blank" >RIV/00216305:26220/05:PU54394 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216305:26220/05:PU51305
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Wide Current Range Potentiostat
Popis výsledku v původním jazyce
In various sphere of industry like in medicine, in agriculture, in food-processing industry or in living environment is needed to recognize matters of analyte. Analyte is the matter we determine. To determining a matter in scaned solution we use sensors.A sensors made by thick film technology are the substrate for production of biosensors. Biosensor is analytical instrument containing sensitive element biological origin, which is part of it or in tight contact with physical-chemical convertor. It proviides running electronical signal, which is commensurable to concentration one or some (group) of chemical matters in a sample. Acquired signal for next processing reach very small value of current or voltage. Measured current from microelectrodes reach values from pA to mA. Whole system is optimized for measuring these small values of magnitudes. For measuring is used method of cyclic voltammetry, where is analyzed current response on triangle input voltage. Current response is logarithm
Název v anglickém jazyce
Wide Current Range Potentiostat
Popis výsledku anglicky
In various sphere of industry like in medicine, in agriculture, in food-processing industry or in living environment is needed to recognize matters of analyte. Analyte is the matter we determine. To determining a matter in scaned solution we use sensors.A sensors made by thick film technology are the substrate for production of biosensors. Biosensor is analytical instrument containing sensitive element biological origin, which is part of it or in tight contact with physical-chemical convertor. It proviides running electronical signal, which is commensurable to concentration one or some (group) of chemical matters in a sample. Acquired signal for next processing reach very small value of current or voltage. Measured current from microelectrodes reach values from pA to mA. Whole system is optimized for measuring these small values of magnitudes. For measuring is used method of cyclic voltammetry, where is analyzed current response on triangle input voltage. Current response is logarithm
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
EDS '05 IMAPS CS INTERNATIONAL CONFERENCE PROCEEDINGS
ISBN
80-214-2990-9
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
21-24
Název nakladatele
Z. Novotny
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
15. 9. 2005
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—