Analýza a výzkum pulsů kardiostimulátorů
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F06%3APU58779" target="_blank" >RIV/00216305:26220/06:PU58779 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analysis And Research Of The Pacemaker Pulse Parameters
Popis výsledku v původním jazyce
The dysfunction of the pacemaker (PM) system could be dysfunction of pacemaker itself, or dysfunction of electrode. Number of PM dysfunctions is relative small, and it is not so hard to identify. Dysfunction of electrode (connection problems, infraction,insulation defect) could be life threathing as-well, but detection of this event type is still problem - a measurement method is needed with which the functionality of pacemaker systems in patients can be judged. This prompted a research project to construct device for acquiring pacemaker stimulation pulse together with the analysis software based on PC - hypothesis of the project is that dysfunction of the electrode will cause the change of stimulation pulse on surface ECG. Clearly, it is necessary todescribe and analyze several pulse parameters of pacemakers with special hardware and software system. Values of pulse parameters and their significance aren't well known yet. The aim of this article is explanation and description of dev
Název v anglickém jazyce
Analysis And Research Of The Pacemaker Pulse Parameters
Popis výsledku anglicky
The dysfunction of the pacemaker (PM) system could be dysfunction of pacemaker itself, or dysfunction of electrode. Number of PM dysfunctions is relative small, and it is not so hard to identify. Dysfunction of electrode (connection problems, infraction,insulation defect) could be life threathing as-well, but detection of this event type is still problem - a measurement method is needed with which the functionality of pacemaker systems in patients can be judged. This prompted a research project to construct device for acquiring pacemaker stimulation pulse together with the analysis software based on PC - hypothesis of the project is that dysfunction of the electrode will cause the change of stimulation pulse on surface ECG. Clearly, it is necessary todescribe and analyze several pulse parameters of pacemakers with special hardware and software system. Values of pulse parameters and their significance aren't well known yet. The aim of this article is explanation and description of dev
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 2006 Summer Bioengineering Conference
ISBN
0-7918-3773-4
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
237-238
Název nakladatele
The Bioengineering Division of the American Society of Mechanical Engineers
Místo vydání
Amelia Plantation Island, Florida, USA
Místo konání akce
Amelia Island Plantation, Amelia Island, Florida
Datum konání akce
21. 6. 2006
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—