Měření časových charakteristik gradientních magnetických polí
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F06%3APU61525" target="_blank" >RIV/00216305:26220/06:PU61525 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measurements of time characteristics of the gradient magnetic field
Popis výsledku v původním jazyce
Imaging techniques based on the principles of nuclear magnetic resonance (NMR) are modern techniques for the study of chemical, biological and physical properties of substances. The most important are their applications in medical sciences. MR imaging ofa specimen weighted with diffusion coefficients requires very accurate data on the time course of the gradient pulse. Diffusion coefficients are determined from the drop of the MR signal measured with and without the application of magnetic field gradients. From the accuracy point of view, the defined course of gradients plays an important role in the computation of coefficients. A minimum rise and fall times, a defined magnitude of the excited gradient of the magnetic field and a symmetry of positiveand negative pulses (zero integral of pulses of the same magnitude and opposite polarities) are required. To characterize the time course of gradient pulses or either polarity, simple methods of their measurement has been developed and ex
Název v anglickém jazyce
Measurements of time characteristics of the gradient magnetic field
Popis výsledku anglicky
Imaging techniques based on the principles of nuclear magnetic resonance (NMR) are modern techniques for the study of chemical, biological and physical properties of substances. The most important are their applications in medical sciences. MR imaging ofa specimen weighted with diffusion coefficients requires very accurate data on the time course of the gradient pulse. Diffusion coefficients are determined from the drop of the MR signal measured with and without the application of magnetic field gradients. From the accuracy point of view, the defined course of gradients plays an important role in the computation of coefficients. A minimum rise and fall times, a defined magnitude of the excited gradient of the magnetic field and a symmetry of positiveand negative pulses (zero integral of pulses of the same magnitude and opposite polarities) are required. To characterize the time course of gradient pulses or either polarity, simple methods of their measurement has been developed and ex
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the International Workshop ISEP - UTEE 3. - 6. 9. 2006 Paris
ISBN
80-214-3250-0
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
1-6
Název nakladatele
L'Institut Supérieur d'Electronique de Paris, Paris, France
Místo vydání
L'Institut Supérieur d'Electronique de Pari
Místo konání akce
L'Institut Supérieur d'Electronique de Pari
Datum konání akce
3. 9. 2006
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—