Měření a simulace vliv materiálu v MR tomografii
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F06%3APU61666" target="_blank" >RIV/00216305:26220/06:PU61666 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measurement and simulation of material influence in MR tomography
Popis výsledku v původním jazyce
Materials with different electrical conductivity and/or magnetic susceptibility can cause deformation of magnetic field in MR tomograph, resulting in errors in obtained image. Using simulation and experimental verification we can solve the effect of changes in homogeneity of static and HF magnetic fields caused by specimen made from conductive and/or magnetic material in MR tomograph. This paper describes theoretical base and experimental measurement of the magnetic resonance imaging method for susceptibility measurement. Described technique is suitable for substances with no signal in MR tomography. The method uses deformation of magnetic induction field in specimen vicinity. For MR purposes it is necessary to immerse specimen into reference medium with measurable MR signal (demineralized water is suitable). Shape of magnetic field changed by specimen impact (reaction field) we measure by means of Gradient Echo (GE) measuring method.
Název v anglickém jazyce
Measurement and simulation of material influence in MR tomography
Popis výsledku anglicky
Materials with different electrical conductivity and/or magnetic susceptibility can cause deformation of magnetic field in MR tomograph, resulting in errors in obtained image. Using simulation and experimental verification we can solve the effect of changes in homogeneity of static and HF magnetic fields caused by specimen made from conductive and/or magnetic material in MR tomograph. This paper describes theoretical base and experimental measurement of the magnetic resonance imaging method for susceptibility measurement. Described technique is suitable for substances with no signal in MR tomography. The method uses deformation of magnetic induction field in specimen vicinity. For MR purposes it is necessary to immerse specimen into reference medium with measurable MR signal (demineralized water is suitable). Shape of magnetic field changed by specimen impact (reaction field) we measure by means of Gradient Echo (GE) measuring method.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the International Workshop ISEP - UTEE 3. - 6. 9. 2006 Paris
ISBN
80-214-3250-0
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
87-92
Název nakladatele
L'Institut Supérieur d'Electronique de Paris, Paris, France
Místo vydání
L'Institut Supérieur d'Electronique de Pari
Místo konání akce
L'Institut Supérieur d'Electronique de Pari
Datum konání akce
3. 9. 2006
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—