This paper focuses to deal with the design of an mixed signal ASIC single chip measurement system for (i) embedded digital sensing of TFT biosensors and (ii) system programming (hardware & software). This ASIC monolithic measurement system is embedded onthick film amperometric sensors. The sensor applies fused alumina substrate processed by thick film technology. The ASIC prototype prepared in CMOS 0.7 ?m technol-ogy contains mixed signal analog measurement block and programmable digital calibration EPROM memory located on one chip. The digital part of the chip of the smart sensor contains 48 OTP (One Time Programma-ble) cells that are supposed to store calibration data for the precious measurement. The programmer is based on the ATMEL microcontroller. The full system is con-trolled by developed PC software. PC and programmer communicate with the biosensor with embedded ASIC chip via a USB interface.
Název v anglickém jazyce
New precise intrumentation for electrochemical analysis
Popis výsledku anglicky
This paper focuses to deal with the design of an mixed signal ASIC single chip measurement system for (i) embedded digital sensing of TFT biosensors and (ii) system programming (hardware & software). This ASIC monolithic measurement system is embedded onthick film amperometric sensors. The sensor applies fused alumina substrate processed by thick film technology. The ASIC prototype prepared in CMOS 0.7 ?m technol-ogy contains mixed signal analog measurement block and programmable digital calibration EPROM memory located on one chip. The digital part of the chip of the smart sensor contains 48 OTP (One Time Programma-ble) cells that are supposed to store calibration data for the precious measurement. The programmer is based on the ATMEL microcontroller. The full system is con-trolled by developed PC software. PC and programmer communicate with the biosensor with embedded ASIC chip via a USB interface.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GD102%2F03%2FH105" target="_blank" >GD102/03/H105: Moderní metody řešení, návrhu a aplikace elektronických obvodů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Electronic Devices and Systems IMAPS CS International Conference 2006 and Training in Innovative Technologies for the Development of Electronic Products - Workshop
ISBN
80-214-3246-2
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
1-4
Název nakladatele
NEUVEDEN
Místo vydání
NEUVEDEN
Místo konání akce
Brno
Datum konání akce
14. 9. 2006
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—