Více kanálové měření částečných výbojů
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F06%3APU65004" target="_blank" >RIV/00216305:26220/06:PU65004 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Multichannel PD Measurement
Popis výsledku v původním jazyce
This work is focused on PC supported multi channel Partial Discharge (PD) measurement. The partial discharge is regarded as a parasitic effect occurring in insulating systems. Occurrences of partial discharge can be considered quite random effect. Partial discharge can be monitored in electronic circuits which work with high voltage and also with high frequency in the range of some tents of kHz. Especially on turning machines, in integrated circuits where the applied voltage is substantially lower can monitored, but conducting routes dimensions are substantially more closely together. Each fault in insulation (air bubble) between conducting routes can lead from some voltage level to lighting a discharge and subsequent degradation of insulation parameters and it can lead to an electrical breakdown. In this designed system it is possible determine amplitudes of peaks due to adjustable level detection and eliminate the rests of carrier wave and possible noise. All issues of measurements a
Název v anglickém jazyce
Multichannel PD Measurement
Popis výsledku anglicky
This work is focused on PC supported multi channel Partial Discharge (PD) measurement. The partial discharge is regarded as a parasitic effect occurring in insulating systems. Occurrences of partial discharge can be considered quite random effect. Partial discharge can be monitored in electronic circuits which work with high voltage and also with high frequency in the range of some tents of kHz. Especially on turning machines, in integrated circuits where the applied voltage is substantially lower can monitored, but conducting routes dimensions are substantially more closely together. Each fault in insulation (air bubble) between conducting routes can lead from some voltage level to lighting a discharge and subsequent degradation of insulation parameters and it can lead to an electrical breakdown. In this designed system it is possible determine amplitudes of peaks due to adjustable level detection and eliminate the rests of carrier wave and possible noise. All issues of measurements a
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Electronic System Design 2006, Socrates International Conference Proceedings
ISBN
978-960-8025-99-8
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
129-132
Název nakladatele
Chania, Crete Institute of Technology, Greece
Místo vydání
Chania, Greece
Místo konání akce
Brno
Datum konání akce
16. 10. 2006
Typ akce podle státní příslušnosti
EUR - Evropská akce