Comparison of linear and peristaltic pump for continuous flow methods
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F06%3APU81415" target="_blank" >RIV/00216305:26220/06:PU81415 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
čeština
Název v původním jazyce
Comparison of linear and peristaltic pump for continuous flow methods
Popis výsledku v původním jazyce
The object of this work was a comparison of linear and peristaltic pump, their characteristics discovering and a decision on their suitability for continuous flow analysis (CFA). An amperometric biosensor was applied for the measurement and it was detecting a current response to hydrogen peroxide oxidization. The linear pump showed better characteristics for CFA. The peristaltic pump is also suitable, but its flow pulses make measurement evaluation more difficult. Optimal pump revolutions were set for continuous flow system. It was 200 rpm to 3000 rpm for the linear pump and more then 6000 rpm for the peristaltic pump.
Název v anglickém jazyce
Comparison of linear and peristaltic pump for continuous flow methods
Popis výsledku anglicky
The object of this work was a comparison of linear and peristaltic pump, their characteristics discovering and a decision on their suitability for continuous flow analysis (CFA). An amperometric biosensor was applied for the measurement and it was detecting a current response to hydrogen peroxide oxidization. The linear pump showed better characteristics for CFA. The peristaltic pump is also suitable, but its flow pulses make measurement evaluation more difficult. Optimal pump revolutions were set for continuous flow system. It was 200 rpm to 3000 rpm for the linear pump and more then 6000 rpm for the peristaltic pump.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 12th Conference STUDENT EEICT 2006
ISBN
80-214-3160-1
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
—
Název nakladatele
Neuveden
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
27. 4. 2006
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—