One of the major problems in power quality is a volt-age fluctuation that causes fluctuation of luminous flux of light sources and the disturbing light flicker can occur consequently. Fluctuation of supply voltage is primary viewed, for historical reason, as voltage amplitude modulation (AM) and the response of UIE/IEC flickermeter, which is based on incandescent bulb - human eye - brain scheme, is designed exactly for such fluctuation. From another point of view, a voltage magnitude fluctuation could be introduced also by subharmonic and/or interharmonic components superimposed on a voltage waveform. The boundary interharmonic frequency of a voltage AM is approx. double of fundamental system frequency (f1) and for this reason the response of the standard UIE/IEC flickermeter to interhar-monic voltages is also up to 2* f1. Nevertheless, high frequency voltage interharmonics (over 100 Hz) are likewise able to produce light flicker. That is valid for all lamps, except incandescent. And t
Název v anglickém jazyce
A time domain based flickermeter with response to a voltage variation caused by high frequency interharmonics
Popis výsledku anglicky
One of the major problems in power quality is a volt-age fluctuation that causes fluctuation of luminous flux of light sources and the disturbing light flicker can occur consequently. Fluctuation of supply voltage is primary viewed, for historical reason, as voltage amplitude modulation (AM) and the response of UIE/IEC flickermeter, which is based on incandescent bulb - human eye - brain scheme, is designed exactly for such fluctuation. From another point of view, a voltage magnitude fluctuation could be introduced also by subharmonic and/or interharmonic components superimposed on a voltage waveform. The boundary interharmonic frequency of a voltage AM is approx. double of fundamental system frequency (f1) and for this reason the response of the standard UIE/IEC flickermeter to interhar-monic voltages is also up to 2* f1. Nevertheless, high frequency voltage interharmonics (over 100 Hz) are likewise able to produce light flicker. That is valid for all lamps, except incandescent. And t
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GP102%2F08%2FP582" target="_blank" >GP102/08/P582: Výzkum rušivého kolísání světelného toku světelných zdrojů způsobeného přítomností harmonických a meziharmonických složek v napájecím napětí</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings ot the 9th International Scientific Conference Electric Power Engineering 2008
ISBN
978-80-214-3650-3
ISSN
—
e-ISSN
—
Počet stran výsledku
10
Strana od-do
—
Název nakladatele
Brno University of Technology, FEEC, Department of Electrical Power Engineering
Místo vydání
Brno, Czech Republic
Místo konání akce
Hotel Santon, Brno
Datum konání akce
13. 5. 2008
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
000263964600026