Progress in Primary Calibration of Acoustic Emission Sensors
Popis výsledku v původním jazyce
The paper reviews the background of the primary calibration of acoustic emission sensors and the determination of uncertainty by this calibration. There are discussed the aims and the purpose of the primary calibration and main sources of uncertainty inpractical usage of calibration results. The comparison of the results of the both method is presented. The shape of calibration characteristics corresponds well up to 500 kHz. The calculation of the uncertainty in the reciprocity and step function calibration is closely described. The problem of propagation of uncertainty in the fast fourier algorithm was solved. Uncertainty of measurement by primary calibration is determined and presented in the paper. The uncertainty in reciprocity calibration of UT 1000 in range from 60 kHz to 285 kHz was +-3dB and from 285 kHz to 1 MHz up to +-8 dB and the same results in the calibration by step function. The calculation of the uncertainty includes all the presumable sources. Such as variation of in
Název v anglickém jazyce
Progress in Primary Calibration of Acoustic Emission Sensors
Popis výsledku anglicky
The paper reviews the background of the primary calibration of acoustic emission sensors and the determination of uncertainty by this calibration. There are discussed the aims and the purpose of the primary calibration and main sources of uncertainty inpractical usage of calibration results. The comparison of the results of the both method is presented. The shape of calibration characteristics corresponds well up to 500 kHz. The calculation of the uncertainty in the reciprocity and step function calibration is closely described. The problem of propagation of uncertainty in the fast fourier algorithm was solved. Uncertainty of measurement by primary calibration is determined and presented in the paper. The uncertainty in reciprocity calibration of UT 1000 in range from 60 kHz to 285 kHz was +-3dB and from 285 kHz to 1 MHz up to +-8 dB and the same results in the calibration by step function. The calculation of the uncertainty includes all the presumable sources. Such as variation of in
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA101%2F06%2F1689" target="_blank" >GA101/06/1689: Analýza komponent modelu systému pro metodu akustické emise</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Acoustics'08 Paris Proceedings on CD-ROM
ISBN
978-2-9521105-4-9
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
—
Název nakladatele
SFA
Místo vydání
Paříž, Francie
Místo konání akce
Paříž, Francie
Datum konání akce
29. 6. 2008
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—