Optimalizace elektrochemického analytického zařízení pro měření s tlustovrstvými elektrochemickými senzory
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F08%3APU77354" target="_blank" >RIV/00216305:26220/08:PU77354 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Optimization of electrochemical analytical device for measurements with thick-film electrochemical sensors
Popis výsledku v původním jazyce
Paper covers an area of electrochemical analytical devices that are made especially for measurements with thick-film electrochemical sensors. There were made several improvements of own designed electrochemical analytical device with rotating vessel in this work. The improvement was done on sensor holder to ensure reproducible sensor placing in the vessel and electronic control part that was optimized for better performance of analytical device prototype. The best current response of the sensor was investigated in dependence on sensor position in the system in potassium ferro-ferricyanide solution. Obtained results have been plotted out in 3D graphs of current response in the set positions. Finally the mass flow optimized sensor response was investigated and compared with a standard one.
Název v anglickém jazyce
Optimization of electrochemical analytical device for measurements with thick-film electrochemical sensors
Popis výsledku anglicky
Paper covers an area of electrochemical analytical devices that are made especially for measurements with thick-film electrochemical sensors. There were made several improvements of own designed electrochemical analytical device with rotating vessel in this work. The improvement was done on sensor holder to ensure reproducible sensor placing in the vessel and electronic control part that was optimized for better performance of analytical device prototype. The best current response of the sensor was investigated in dependence on sensor position in the system in potassium ferro-ferricyanide solution. Obtained results have been plotted out in 3D graphs of current response in the set positions. Finally the mass flow optimized sensor response was investigated and compared with a standard one.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/KAN208130801" target="_blank" >KAN208130801: Nové konstrukce a využití nanobiosenzorů a nanosenzorů v medicíně (NANOSEMED)</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electronics
ISSN
1313-1842
e-ISSN
—
Svazek periodika
17
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
BG - Bulharská republika
Počet stran výsledku
6
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—