Referenční elektrody pro tlustovrstvé senzory
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F08%3APU77709" target="_blank" >RIV/00216305:26220/08:PU77709 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Reference Electrodes for Thick-Film Sensors
Popis výsledku v původním jazyce
Paper deals with a problematic of thick-film electrochemical sensors for trace analysis of species or elements in aqueous solutions. A problem of replacement of classical Ag/AgCl reference electrodes by planar thick-film electrodes is discussed here. Inthis paper there were compared several thick-film reference electrodes with classical ones using the same electrochemical arrangement. Special commercial thick-film pastes and electrochemically fabricated Ag/AgCl layers were used for reference electrodesof thick-film electrochemical sensors and characterized in standard electrochemical solution of potassium ferro-ferricyanide. First results show big difference between tested materials, mainly in shifts of half weave potentials. Moreover with use of screen-printed reference electrodes, there was shown a high output current dependence on the change of electrodes distances.
Název v anglickém jazyce
Reference Electrodes for Thick-Film Sensors
Popis výsledku anglicky
Paper deals with a problematic of thick-film electrochemical sensors for trace analysis of species or elements in aqueous solutions. A problem of replacement of classical Ag/AgCl reference electrodes by planar thick-film electrodes is discussed here. Inthis paper there were compared several thick-film reference electrodes with classical ones using the same electrochemical arrangement. Special commercial thick-film pastes and electrochemically fabricated Ag/AgCl layers were used for reference electrodesof thick-film electrochemical sensors and characterized in standard electrochemical solution of potassium ferro-ferricyanide. First results show big difference between tested materials, mainly in shifts of half weave potentials. Moreover with use of screen-printed reference electrodes, there was shown a high output current dependence on the change of electrodes distances.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA102%2F08%2F1546" target="_blank" >GA102/08/1546: Miniaturizované inteligentní systémy a nanostrukturované elektrody pro chemické, biologické a farmaceutické aplikace (NANIMEL)</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
ISSE 2008 Conference Proceedings
ISBN
978-963-06-4915-5
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
Neuveden
Místo vydání
Budapest, Hungary
Místo konání akce
Budapest
Datum konání akce
7. 5. 2008
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—