Na tlustovrstvém senzoru integrovaný mikropotenciostat pro analýzu těžkých kovů
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F08%3APU78018" target="_blank" >RIV/00216305:26220/08:PU78018 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Embedded micropotetiostat on screen-printed sensor for heavy metals analysis
Popis výsledku v původním jazyce
Presented paper deals with the problematic of easy on-field, fast and low-cost monitoring of species or elements contained in biological samples and/or environment. For this purpose the screen-printed thick-film electrochemical sensor with embedded micropotentiostat have been designed and used for determination of cadmium and led in aqueous solution contrary to toxic mercury drop electrode and big scale measurement devices that are usually used for such analyses in laboratories. The micropotentiostat iscontrolled by a personal computer. It provides the same measurement methods like big commercial laboratory devices (CV, DPV, etc.). The advantage of such microsystem is that the noise ratio caused by leads is reduced because the low signal from the electrodes to the micropotentiostat is not transmitted through additional wires or connectors. Presented microsystem has been used for detection of Cd(II) and Pb(II) ions in this work. We were able to determine units of uM of the metals.
Název v anglickém jazyce
Embedded micropotetiostat on screen-printed sensor for heavy metals analysis
Popis výsledku anglicky
Presented paper deals with the problematic of easy on-field, fast and low-cost monitoring of species or elements contained in biological samples and/or environment. For this purpose the screen-printed thick-film electrochemical sensor with embedded micropotentiostat have been designed and used for determination of cadmium and led in aqueous solution contrary to toxic mercury drop electrode and big scale measurement devices that are usually used for such analyses in laboratories. The micropotentiostat iscontrolled by a personal computer. It provides the same measurement methods like big commercial laboratory devices (CV, DPV, etc.). The advantage of such microsystem is that the noise ratio caused by leads is reduced because the low signal from the electrodes to the micropotentiostat is not transmitted through additional wires or connectors. Presented microsystem has been used for detection of Cd(II) and Pb(II) ions in this work. We were able to determine units of uM of the metals.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA102%2F08%2F1546" target="_blank" >GA102/08/1546: Miniaturizované inteligentní systémy a nanostrukturované elektrody pro chemické, biologické a farmaceutické aplikace (NANIMEL)</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the conference Eurosensors XXII
ISBN
978-3-00-025217-4
ISSN
—
e-ISSN
—
Počet stran výsledku
3
Strana od-do
—
Název nakladatele
VDI/VDE-Gesellschaft Mess- und Automatisierungstechnik (GMA)
Místo vydání
Dresden, Německo
Místo konání akce
Dresden
Datum konání akce
7. 9. 2008
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—