Some Features of Possible Solutions of Installing Telecontrolled Section Switches and Reclosers in the MV Overhead Network
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F09%3APU87966" target="_blank" >RIV/00216305:26220/09:PU87966 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Some Features of Possible Solutions of Installing Telecontrolled Section Switches and Reclosers in the MV Overhead Network
Popis výsledku v původním jazyce
The paper discusses some features of possible solutions of placing telecontrolled section switches and reclosers in the MV overhead network. The presented results are derived from examples of real MV feeders. The reliability and economical indices beingevaluated have been obtained from the non-sequential Monte Carlo simulation. The financial evaluation of reliability is based on the customer's standard of electricity supply continuity which is being introduced by some regulator offices. This standard defines the limit of the annual number of supply interruptions and the limit of the total annual duration of supply interruptions sustained by the customer. Costs of penalty payments then follow from exceeding some of these limits. The inclusion of both limits into the standard and thus into the economical evaluation results in changing the relation between the net present value of possible solutions and the reliability index SAIDI. It also leads to preferring reclosers to telecontrolled
Název v anglickém jazyce
Some Features of Possible Solutions of Installing Telecontrolled Section Switches and Reclosers in the MV Overhead Network
Popis výsledku anglicky
The paper discusses some features of possible solutions of placing telecontrolled section switches and reclosers in the MV overhead network. The presented results are derived from examples of real MV feeders. The reliability and economical indices beingevaluated have been obtained from the non-sequential Monte Carlo simulation. The financial evaluation of reliability is based on the customer's standard of electricity supply continuity which is being introduced by some regulator offices. This standard defines the limit of the annual number of supply interruptions and the limit of the total annual duration of supply interruptions sustained by the customer. Costs of penalty payments then follow from exceeding some of these limits. The inclusion of both limits into the standard and thus into the economical evaluation results in changing the relation between the net present value of possible solutions and the reliability index SAIDI. It also leads to preferring reclosers to telecontrolled
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IEEE Power and Energy Society General Meeting-PESGM
ISBN
978-1-4244-4240-9
ISSN
—
e-ISSN
—
Počet stran výsledku
500
Strana od-do
—
Název nakladatele
IEEE
Místo vydání
345 E 47TH ST, NEW YORK, NY 10017 USA
Místo konání akce
Calgary
Datum konání akce
26. 7. 2009
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000275524901173