EMCCD optical mapping system for measurement of action potentials
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F10%3APR24318" target="_blank" >RIV/00216305:26220/10:PR24318 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
EMCCD optical mapping system for measurement of action potentials
Popis výsledku v původním jazyce
Optical mapping using membrane potential-sensitive fluorescent dyes provides a means of recording electrical activation on the heart surface with high spatial resolution. However, in order to interpret these data, it is necessary to correct for artifactsintroduced by heart wall motion. The new optical system based on EMCCD camera is designed to be able to record optical signal in high resolution 128x128 at 400fps (via a 550nm> long-pass filter). The system allows use of new ratiometric technique. Imagesequences can be recorded sequentially with and without a second long-pass filter (620nm>) which is introduced into the light path using a fast purpose-built translation system. The system consist of the novel chamber design which allows simultaneouslyrecordings of optical signal on the one side of the heart as well as electrical on another one, all in physiological temperatures. The heart is illuminated with 2 blue LEDs (Luxen V Star, LHXL-LB5C), each equipped with a small reflector,
Název v anglickém jazyce
EMCCD optical mapping system for measurement of action potentials
Popis výsledku anglicky
Optical mapping using membrane potential-sensitive fluorescent dyes provides a means of recording electrical activation on the heart surface with high spatial resolution. However, in order to interpret these data, it is necessary to correct for artifactsintroduced by heart wall motion. The new optical system based on EMCCD camera is designed to be able to record optical signal in high resolution 128x128 at 400fps (via a 550nm> long-pass filter). The system allows use of new ratiometric technique. Imagesequences can be recorded sequentially with and without a second long-pass filter (620nm>) which is introduced into the light path using a fast purpose-built translation system. The system consist of the novel chamber design which allows simultaneouslyrecordings of optical signal on the one side of the heart as well as electrical on another one, all in physiological temperatures. The heart is illuminated with 2 blue LEDs (Luxen V Star, LHXL-LB5C), each equipped with a small reflector,
Klasifikace
Druh
G<sub>funk</sub> - Funkční vzorek
CEP obor
JD - Využití počítačů, robotika a její aplikace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA102%2F07%2F1473" target="_blank" >GA102/07/1473: Optické metody registrace elektrických potenciálů a koncentrace vápníku v srdci s laserovou stabilizací</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Interní identifikační kód produktu
OMS
Číselná identifikace
—
Technické parametry
Funkční vzorek je využíván na Department of Physiology, Room# 2224, 85 Park Rd..,Grafton, Auckland, New Zealand Fotografie a technicke paramety na webu: http://biomedheartproject.webs.com/ Technicke parametry: Kamera: EMCCD Cascade 128+, 128x128,
Ekonomické parametry
Cena 600000 Kč
Kategorie aplik. výsledku dle nákladů
—
IČO vlastníka výsledku
00216305
Název vlastníka
Ústav biomedicínského inženýrství
Stát vlastníka
CZ - Česká republika
Druh možnosti využití
N - Využití výsledku jiným subjektem je možné bez nabytí licence (výsledek není licencován)
Požadavek na licenční poplatek
—
Adresa www stránky s výsledkem
—