New Ways of Non-invasive Measuring of Blood Circulation Parameters
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F10%3APU86131" target="_blank" >RIV/00216305:26220/10:PU86131 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
New Ways of Non-invasive Measuring of Blood Circulation Parameters
Popis výsledku v původním jazyce
The purpose of the article is to describe possible ways of non-invasive measuring and analysis of blood circulation parameters. These parameters are very important indicators of various cardiovascular diseases in clinical practice. For this purpose, methods of purely non-invasive analysis are sought. A standard approach is to use an inflatable cuff for blood pressure monitoring and analysis, using different methods of measuring, typically systolic, diastolic, mean and, less commonly, continuous blood pressure values. Inflatable cuff is a device decrementing a patient's comfort, namely by long-time (24 and more hours) monitoring. In this article, three principles of purely non-invasive (without inflatable cuff) measurement are described together with some experimental results. The first method described is based on a reliable detection of artery sectional area in the video sequence of B-mode ultrasound images using the Lucas-Canade optical flow determination technique. The output of thi
Název v anglickém jazyce
New Ways of Non-invasive Measuring of Blood Circulation Parameters
Popis výsledku anglicky
The purpose of the article is to describe possible ways of non-invasive measuring and analysis of blood circulation parameters. These parameters are very important indicators of various cardiovascular diseases in clinical practice. For this purpose, methods of purely non-invasive analysis are sought. A standard approach is to use an inflatable cuff for blood pressure monitoring and analysis, using different methods of measuring, typically systolic, diastolic, mean and, less commonly, continuous blood pressure values. Inflatable cuff is a device decrementing a patient's comfort, namely by long-time (24 and more hours) monitoring. In this article, three principles of purely non-invasive (without inflatable cuff) measurement are described together with some experimental results. The first method described is based on a reliable detection of artery sectional area in the video sequence of B-mode ultrasound images using the Lucas-Canade optical flow determination technique. The output of thi
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/2B06111" target="_blank" >2B06111: Nové diagnostické metody zjišťování parametrů oběhového systému založené na infračerveném snímání obrazu krevního řečiště.</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
WSEAS Transactions on Signal Processing
ISSN
1790-5052
e-ISSN
—
Svazek periodika
2010
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
GR - Řecká republika
Počet stran výsledku
11
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—