Testing of Appliances Immunity to Voltage Dips and Short Interruptions under Laboratory Conditions and Practical Usage of Results
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F10%3APU86589" target="_blank" >RIV/00216305:26220/10:PU86589 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Testing of Appliances Immunity to Voltage Dips and Short Interruptions under Laboratory Conditions and Practical Usage of Results
Popis výsledku v původním jazyce
Recently monitoring of electric appliances immunity to the voltage dips and short interruptions has increasing importance. It is due to implementation of power electronic converters and electronic-based control units in many types of the electric appliances - number of threatened appli-ances is greater from year to year. Appliances sensitivity to the voltage dips and short interruptions use to be tested in laboratories, but in most cases the laboratory conditions are entirely different than the conditions in which appli-ances use to run for most of the time of its life. This differ-ence greatly declines the reproducibility of the measured results because practically it is not possible to verify them in real usage of the tested appliance. Influencing parame-ters statement with theirs description as well as a proposal of methodical procedure for increasing of reproducibility degree of the laboratory results to practice is content of this paper.
Název v anglickém jazyce
Testing of Appliances Immunity to Voltage Dips and Short Interruptions under Laboratory Conditions and Practical Usage of Results
Popis výsledku anglicky
Recently monitoring of electric appliances immunity to the voltage dips and short interruptions has increasing importance. It is due to implementation of power electronic converters and electronic-based control units in many types of the electric appliances - number of threatened appli-ances is greater from year to year. Appliances sensitivity to the voltage dips and short interruptions use to be tested in laboratories, but in most cases the laboratory conditions are entirely different than the conditions in which appli-ances use to run for most of the time of its life. This differ-ence greatly declines the reproducibility of the measured results because practically it is not possible to verify them in real usage of the tested appliance. Influencing parame-ters statement with theirs description as well as a proposal of methodical procedure for increasing of reproducibility degree of the laboratory results to practice is content of this paper.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 11th International Scientific Conference Elecric Power Engineering 2010
ISBN
978-80-214-4094-4
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
—
Název nakladatele
Brno University of Technology, FEEC, Department of Electrical Power Engineering
Místo vydání
Brno
Místo konání akce
Hotel Santon, Brno
Datum konání akce
4. 5. 2010
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—