A Light - flickermeter - Part I: Design
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F10%3APU86613" target="_blank" >RIV/00216305:26220/10:PU86613 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A Light - flickermeter - Part I: Design
Popis výsledku v původním jazyce
Voltage variation is one of lamps flickering main cause; thus evaluation of a disturbing light flicker is a part of voltage quality classification. The instrument for flicker level measurement by means of voltage variation analysis is named flickermeterand is specified in standard EN 61000-4-15. The flickermeter is a specialized analyzer modeling response of a chain consisting of reference 60W incandescent lamp - eye - brain of an average observer. Hence, other lamp types like discharge are mainly usedin illumination systems at present, significant difference between flicker measurement using the standard flickermeter and observation can appear. In the paper, there is proposed a light flicker measurement method based on analysis of an irradiance (radiant flux) waveform, where the output flicker index is independent on the lamp type. With regard to expected properties the proposed light-flickermeter can be called objective flickermeter. Nevertheless the range of application of the obj
Název v anglickém jazyce
A Light - flickermeter - Part I: Design
Popis výsledku anglicky
Voltage variation is one of lamps flickering main cause; thus evaluation of a disturbing light flicker is a part of voltage quality classification. The instrument for flicker level measurement by means of voltage variation analysis is named flickermeterand is specified in standard EN 61000-4-15. The flickermeter is a specialized analyzer modeling response of a chain consisting of reference 60W incandescent lamp - eye - brain of an average observer. Hence, other lamp types like discharge are mainly usedin illumination systems at present, significant difference between flicker measurement using the standard flickermeter and observation can appear. In the paper, there is proposed a light flicker measurement method based on analysis of an irradiance (radiant flux) waveform, where the output flicker index is independent on the lamp type. With regard to expected properties the proposed light-flickermeter can be called objective flickermeter. Nevertheless the range of application of the obj
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GP102%2F08%2FP582" target="_blank" >GP102/08/P582: Výzkum rušivého kolísání světelného toku světelných zdrojů způsobeného přítomností harmonických a meziharmonických složek v napájecím napětí</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proccedings of the 11th International Scientific Conference Electric Power Engineering 2010
ISBN
978-80-214-4094-4
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
—
Název nakladatele
Brno University of Technology, FEEC, DEPE
Místo vydání
Brno
Místo konání akce
Hotel Santon, Brno
Datum konání akce
4. 5. 2010
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—