A Light - flickermeter - Part II: Realization and Verification
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F10%3APU86614" target="_blank" >RIV/00216305:26220/10:PU86614 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A Light - flickermeter - Part II: Realization and Verification
Popis výsledku v původním jazyce
The paper is focused on realization and verification of a light-flickermeter simulating response of the average observer on disturbing light flicker under specific conditions. The design of the light-flickermeter is based on digitized the standard UIE/IEC flickermeter measuring scheme where the measuring chain does not include model of the reference incandescent bulb. It means that this type of flickermeter output is expected to be independent on a light source type producing light flicker. The developed instrument evaluates measured luminous flux fluctuation utilizing appropriate hardware and signal processing. The light is sensed by a photodiode with build-in transimpedance amplifier and photopic correction light-filter. The amplifier RC feedback allows control of its transfer function gain and bandwidth. Then the subsequent signal processing is based on NI PXI (cDAQ or cRIO) platform and virtual instrumentation in LabView. For purpose of various type flickermeters verification and c
Název v anglickém jazyce
A Light - flickermeter - Part II: Realization and Verification
Popis výsledku anglicky
The paper is focused on realization and verification of a light-flickermeter simulating response of the average observer on disturbing light flicker under specific conditions. The design of the light-flickermeter is based on digitized the standard UIE/IEC flickermeter measuring scheme where the measuring chain does not include model of the reference incandescent bulb. It means that this type of flickermeter output is expected to be independent on a light source type producing light flicker. The developed instrument evaluates measured luminous flux fluctuation utilizing appropriate hardware and signal processing. The light is sensed by a photodiode with build-in transimpedance amplifier and photopic correction light-filter. The amplifier RC feedback allows control of its transfer function gain and bandwidth. Then the subsequent signal processing is based on NI PXI (cDAQ or cRIO) platform and virtual instrumentation in LabView. For purpose of various type flickermeters verification and c
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GP102%2F08%2FP582" target="_blank" >GP102/08/P582: Výzkum rušivého kolísání světelného toku světelných zdrojů způsobeného přítomností harmonických a meziharmonických složek v napájecím napětí</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proccedings of the 11th International Scientific Conference Electric Power Engineering 2010
ISBN
978-80-214-4094-4
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
—
Název nakladatele
Brno University of Technology, FEEC, DEPE
Místo vydání
Brno
Místo konání akce
Hotel Santon, Brno
Datum konání akce
4. 5. 2010
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—