Modeling of Saturation Characteristic of an Aspiration Condenser
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F10%3APU87058" target="_blank" >RIV/00216305:26220/10:PU87058 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Modeling of Saturation Characteristic of an Aspiration Condenser
Popis výsledku v původním jazyce
It was confirmed that light air ions have positive infuence on human health. For its appraisal it is necessary to know the concentration of air ions and air ion mobility spectrum. This spectrum is usually found out using the saturation characteristic measurement with a gerdien tube; another design option consists in the aspiration condenser with a segmented inner electrode. The second method is faster, but the resolution of air ion mobility spectrum shows worse characteristics.. This paper deals with the mathematical analysis and numerical modeling of saturation characteristic evaluation for this aspiration condenser with a segmented inner electrode. Using a combination of both methods may increase the resolution of air ion mobility spectrum, and the progress of measurement is still better than with the gerdien tube solution.
Název v anglickém jazyce
Modeling of Saturation Characteristic of an Aspiration Condenser
Popis výsledku anglicky
It was confirmed that light air ions have positive infuence on human health. For its appraisal it is necessary to know the concentration of air ions and air ion mobility spectrum. This spectrum is usually found out using the saturation characteristic measurement with a gerdien tube; another design option consists in the aspiration condenser with a segmented inner electrode. The second method is faster, but the resolution of air ion mobility spectrum shows worse characteristics.. This paper deals with the mathematical analysis and numerical modeling of saturation characteristic evaluation for this aspiration condenser with a segmented inner electrode. Using a combination of both methods may increase the resolution of air ion mobility spectrum, and the progress of measurement is still better than with the gerdien tube solution.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
PIERS 2010 in Xi'an Proceedings
ISBN
978-1-934142-12-7
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
—
Název nakladatele
The Electromagnetic Academy
Místo vydání
Cambridge
Místo konání akce
Xi'An, China
Datum konání akce
22. 3. 2010
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—