Errors in Diffusion Coefficients Measurement
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F10%3APU87499" target="_blank" >RIV/00216305:26220/10:PU87499 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Errors in Diffusion Coefficients Measurement
Popis výsledku v původním jazyce
The magnetic resonance (MR) imaging techniques of tomography and spectroscopy are exploited in many applications. The quality of dynamic behavior of gradient magnetic fields is one of the important properties of devices exploiting the phenomenon of magnetic resonance (MR) for imaging or diffusion measurement. A necessary precondition for the facilitation of MR instruments proper functioning consists in the maintenance of a high degree of homogeneity of the fundamental and gradient magnetic fields. Gradient changes induce eddy currents in the surrounding conducting arrangement, thus potentially causing image artifacts, localization errors, and signal distortion. While the use of actively shielded gradients has greatly reduced the magnitude of eddy currents, significant distortion often remains, mainly in the short time interval after the gradient is switched off. Residual eddy currents may require further reduction. This is frequently achieved by pre-emphasis correction in the relevant
Název v anglickém jazyce
Errors in Diffusion Coefficients Measurement
Popis výsledku anglicky
The magnetic resonance (MR) imaging techniques of tomography and spectroscopy are exploited in many applications. The quality of dynamic behavior of gradient magnetic fields is one of the important properties of devices exploiting the phenomenon of magnetic resonance (MR) for imaging or diffusion measurement. A necessary precondition for the facilitation of MR instruments proper functioning consists in the maintenance of a high degree of homogeneity of the fundamental and gradient magnetic fields. Gradient changes induce eddy currents in the surrounding conducting arrangement, thus potentially causing image artifacts, localization errors, and signal distortion. While the use of actively shielded gradients has greatly reduced the magnitude of eddy currents, significant distortion often remains, mainly in the short time interval after the gradient is switched off. Residual eddy currents may require further reduction. This is frequently achieved by pre-emphasis correction in the relevant
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/FR-TI1%2F001" target="_blank" >FR-TI1/001: Výzkum a vývoj detekce výbojové aktivity ve výkonových olejových transformátorech</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
PIERS 2010 Cambridge, Progress In Electromagnetics Research Symposium Proceedings
ISBN
978-1-934142-14-1
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
—
Název nakladatele
Neuveden
Místo vydání
Neuveden
Místo konání akce
Cambridge
Datum konání akce
5. 7. 2010
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—