Electronic System for Mass Screening of Toxic Substances in Environment
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F10%3APU90176" target="_blank" >RIV/00216305:26220/10:PU90176 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electronic System for Mass Screening of Toxic Substances in Environment
Popis výsledku v původním jazyce
The work deals with n-channel system enabling many sample analysis at sort time from sensor array using electrochemical methods. The system is completely based on standard electronics technology as SMT and screen-printing. The 8x12 sensor arrays is formed from 3-electrodes system created on PCB with combination of galvanic deposition and screen-printing special paste on the electrodes which can be used for heavy metal analysis and also biomolecular complexes and organic toxic substances determination. The control unit switches each 3-electrode sensor to 8-channel precise potentiostat which was designed for electrochemical analysis with current sensitivity below 1 pA. The potentiostat can synchronize with control unit to depress time for analysis to minimum. Developed system is able to measure up to eight single inputs and may be simply converted to measure other values, AV or CV characteristics, transfer functions and nonlinear characteristics for example. Measured data will be sent to
Název v anglickém jazyce
Electronic System for Mass Screening of Toxic Substances in Environment
Popis výsledku anglicky
The work deals with n-channel system enabling many sample analysis at sort time from sensor array using electrochemical methods. The system is completely based on standard electronics technology as SMT and screen-printing. The 8x12 sensor arrays is formed from 3-electrodes system created on PCB with combination of galvanic deposition and screen-printing special paste on the electrodes which can be used for heavy metal analysis and also biomolecular complexes and organic toxic substances determination. The control unit switches each 3-electrode sensor to 8-channel precise potentiostat which was designed for electrochemical analysis with current sensitivity below 1 pA. The potentiostat can synchronize with control unit to depress time for analysis to minimum. Developed system is able to measure up to eight single inputs and may be simply converted to measure other values, AV or CV characteristics, transfer functions and nonlinear characteristics for example. Measured data will be sent to
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IEEE Xplore Digital Library, Electronics technology (ISSE), 2010: 33rd International Spring Seminar on Electronics Technology
ISBN
978-1-4244-7850-7
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
—
Název nakladatele
Neuveden
Místo vydání
Warsaw
Místo konání akce
Warsaw
Datum konání akce
12. 5. 2010
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—