Function criteria definition for testing of light sources immunity to voltage dips and short interruptions
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F11%3APU91797" target="_blank" >RIV/00216305:26220/11:PU91797 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Function criteria definition for testing of light sources immunity to voltage dips and short interruptions
Popis výsledku v původním jazyce
The paper deals with light sources immunity level to voltage dips and short interruptions occured in public supply networks. The immunity level of light sources is given by set of parameters relative to chosen function criterion which defines the lamp behaviour during immunity tests. Possible function criteria for light sources immunity tests are defined in the standard EN 61547 and all of them were considered during tests of chosen light sources. For purpose of developed automated test system the function criteria have been converted to measurable signals with corresponding parameters determining limits for function criteria i.e. immunity levels. Using such test system, measurement of immunity curves of chosen lamps has been performed and the results are shown and discussed.
Název v anglickém jazyce
Function criteria definition for testing of light sources immunity to voltage dips and short interruptions
Popis výsledku anglicky
The paper deals with light sources immunity level to voltage dips and short interruptions occured in public supply networks. The immunity level of light sources is given by set of parameters relative to chosen function criterion which defines the lamp behaviour during immunity tests. Possible function criteria for light sources immunity tests are defined in the standard EN 61547 and all of them were considered during tests of chosen light sources. For purpose of developed automated test system the function criteria have been converted to measurable signals with corresponding parameters determining limits for function criteria i.e. immunity levels. Using such test system, measurement of immunity curves of chosen lamps has been performed and the results are shown and discussed.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED0014%2F01%2F01" target="_blank" >ED0014/01/01: Centrum výzkumu a využití obnovitelných zdrojů energie</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 12th International Scientific Conference Electric Power Engineering 2011
ISBN
978-80-248-2393-5
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
1-5
Název nakladatele
VSB - Technical University of Ostrava
Místo vydání
Ostrava
Místo konání akce
Kouty nad Desnou
Datum konání akce
17. 5. 2011
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
000321911500162