Noise Characterization of Cold Emission Cathodes with Epoxy Coating
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F11%3APU91932" target="_blank" >RIV/00216305:26220/11:PU91932 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Noise Characterization of Cold Emission Cathodes with Epoxy Coating
Popis výsledku v původním jazyce
Comprehensive investigation of virgin oxide and resin-coated cold emission cathodes using noise spectroscopic method has been made. The noise spectroscopy in time and frequency domain based upon measuring cathodes voltage noise, was performed in ultrahigh vacuum conditions (UHV) ~ 2 x 10-5 Pa. These conditions decreases the amount of environment interactions with ions and reduces the influence of the electron-induced desorption and adsorption, which poses one of the significant noise sources. For these experiments, cold cathode with epoxy-resin coating was manufactured. A comprehensive investigation was carried out to determine particular noise sources and to compare clean cathodes with the resin-coated one, in order to describe influence of the oxide and dielectric epoxy layer on to the emission current stability. Spectra obtained, for various emission currents at different voltages, are described and explained. The results suggest that the resin-layer changes cathode performance and extends its durability.
Název v anglickém jazyce
Noise Characterization of Cold Emission Cathodes with Epoxy Coating
Popis výsledku anglicky
Comprehensive investigation of virgin oxide and resin-coated cold emission cathodes using noise spectroscopic method has been made. The noise spectroscopy in time and frequency domain based upon measuring cathodes voltage noise, was performed in ultrahigh vacuum conditions (UHV) ~ 2 x 10-5 Pa. These conditions decreases the amount of environment interactions with ions and reduces the influence of the electron-induced desorption and adsorption, which poses one of the significant noise sources. For these experiments, cold cathode with epoxy-resin coating was manufactured. A comprehensive investigation was carried out to determine particular noise sources and to compare clean cathodes with the resin-coated one, in order to describe influence of the oxide and dielectric epoxy layer on to the emission current stability. Spectra obtained, for various emission currents at different voltages, are described and explained. The results suggest that the resin-layer changes cathode performance and extends its durability.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BM - Fyzika pevných látek a magnetismus
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of 5th Annual Internation Travelling Conference for Young Researchers and PhD Students
ISBN
978-80-89347-05-6
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
521-526
Název nakladatele
Harmony Apeiron
Místo vydání
Prešov
Místo konání akce
Tatranská Kotlina
Datum konání akce
13. 4. 2011
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—