A New Approach how to Define the Coefficient of Electroactivity of Adenine and Its Twelve Derivatives Using Flow Injection Analysis with Amperometric Detection
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F11%3APU92514" target="_blank" >RIV/00216305:26220/11:PU92514 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/62157124:16370/11:43870416
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A New Approach how to Define the Coefficient of Electroactivity of Adenine and Its Twelve Derivatives Using Flow Injection Analysis with Amperometric Detection
Popis výsledku v původním jazyce
We studied the electrochemical behaviour of adenine derivates (adenosine, 2 - aminopurine, 2,6 - diaminopurine,6 - benzyl - aminopurine, adenosine - monophosphate, cyclic adenosine monophosphate, nicotin amide adenine dinucleotide, adenosine - triphosphate, S-adenosyl - l - methionine and synthetic derivatives AD -3, AD - 6 and AD-9) using flow injection analysis with electrochemical detection. The influences of pH, flow rate and potential on the signal height of the studied derivates were tested. The optimal pH was 3, the flow rate of the mobile phase 0.75 mL min 1 and the potential 1100 mV. Further, we attempted to characterize each of the studied derivatives by mathematical equations and classic analytical parameters.The lowest detecti on limit wasestimated for adenine as 0.9 nM and 2 - amino - purine as 0.5nM
Název v anglickém jazyce
A New Approach how to Define the Coefficient of Electroactivity of Adenine and Its Twelve Derivatives Using Flow Injection Analysis with Amperometric Detection
Popis výsledku anglicky
We studied the electrochemical behaviour of adenine derivates (adenosine, 2 - aminopurine, 2,6 - diaminopurine,6 - benzyl - aminopurine, adenosine - monophosphate, cyclic adenosine monophosphate, nicotin amide adenine dinucleotide, adenosine - triphosphate, S-adenosyl - l - methionine and synthetic derivatives AD -3, AD - 6 and AD-9) using flow injection analysis with electrochemical detection. The influences of pH, flow rate and potential on the signal height of the studied derivates were tested. The optimal pH was 3, the flow rate of the mobile phase 0.75 mL min 1 and the potential 1100 mV. Further, we attempted to characterize each of the studied derivatives by mathematical equations and classic analytical parameters.The lowest detecti on limit wasestimated for adenine as 0.9 nM and 2 - amino - purine as 0.5nM
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
ELECTROANALYSIS
ISSN
1040-0397
e-ISSN
—
Svazek periodika
23
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
12
Strana od-do
1556-1567
Kód UT WoS článku
000292967900007
EID výsledku v databázi Scopus
—