The paper presents usage of the R-FEM method in the CFX environment. There is describes usage of the sensitivity analysis for improvement of numerical model and change dimensions of numerical model according to radiation pattern and required light distribution. The R-FEM method was used for modeling of special light sources and to compute lighting of surfaces from these sources with very good results. Basic description of the R-FEM method is described below. For modeling of the light sources in the CFXenvironment was used combination of the Finite Volume Method and the radiation method which are included with the CFX (The Discrete Transfer Model and The Monte Carlo Model). Numerical results are presented by model of head-lamp. Sensitivity analysis wasused to change dimensions of numerical model according to lighting distribution.
Název v anglickém jazyce
Design of Lightning Systems with Usage Sensitivity Analysis for Improvement of Numerical Model
Popis výsledku anglicky
The paper presents usage of the R-FEM method in the CFX environment. There is describes usage of the sensitivity analysis for improvement of numerical model and change dimensions of numerical model according to radiation pattern and required light distribution. The R-FEM method was used for modeling of special light sources and to compute lighting of surfaces from these sources with very good results. Basic description of the R-FEM method is described below. For modeling of the light sources in the CFXenvironment was used combination of the Finite Volume Method and the radiation method which are included with the CFX (The Discrete Transfer Model and The Monte Carlo Model). Numerical results are presented by model of head-lamp. Sensitivity analysis wasused to change dimensions of numerical model according to lighting distribution.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Progress In Electromagnetics
ISSN
1559-9450
e-ISSN
—
Svazek periodika
2011
Číslo periodika v rámci svazku
2011
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
5
Strana od-do
465-468
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—