Popis výsledku v původním jazyce
This paper describes design and development of the Maximum Power Point Load (MPPL) - a standalone MCU controlled module offering all the functionality needed for continuous measurement of photovoltaic module I-V curve, MPP point, open circuit voltage andshort circuit current. This module is a part of a complex photovoltaic module efficiency measurement system which is currently being developed by the author. Experimental photovoltaic panel is installed outside the laboratory. Measurement system consists of the solar radiation measurement module (pyranometer), photovoltaic panel load module (MPPL described in this paper) and panel climate measurement module (panel temperature and its distribution, air flow around the panel). Data from measurement modules is being captured via control computer for subsequent analysis of panel efficiency and climatic impacts on it.
Název v anglickém jazyce
Precision Maximum Power Point Tracker
Popis výsledku anglicky
This paper describes design and development of the Maximum Power Point Load (MPPL) - a standalone MCU controlled module offering all the functionality needed for continuous measurement of photovoltaic module I-V curve, MPP point, open circuit voltage andshort circuit current. This module is a part of a complex photovoltaic module efficiency measurement system which is currently being developed by the author. Experimental photovoltaic panel is installed outside the laboratory. Measurement system consists of the solar radiation measurement module (pyranometer), photovoltaic panel load module (MPPL described in this paper) and panel climate measurement module (panel temperature and its distribution, air flow around the panel). Data from measurement modules is being captured via control computer for subsequent analysis of panel efficiency and climatic impacts on it.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA102%2F09%2F0859" target="_blank" >GA102/09/0859: Souvislost lokální emise světla se stochastickými jevy v PN přechodu solárních článků při velmi nízkých teplotách.</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceeing of 26th European Photovoltaic Solar Energy Conference and Exhibition
ISBN
3-936338-27-2
ISSN
—
e-ISSN
—
Počet stran výsledku
3
Strana od-do
3769-3771
Název nakladatele
WIP
Místo vydání
Hamburg
Místo konání akce
Hamburg
Datum konání akce
5. 9. 2011
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—