A Control System for Mobile Forestry Cableway with Hydrostatic Drives: Winding Drums Control
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F11%3APU94754" target="_blank" >RIV/00216305:26220/11:PU94754 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A Control System for Mobile Forestry Cableway with Hydrostatic Drives: Winding Drums Control
Popis výsledku v původním jazyce
The paper deals with wood logging problems and technology. The main part is focused on control of winding drums hydrostatic drives in forestry cableway. The cableway system description is introduced in another contribution. Proportionally controlled hydrostatic pumps are used for supplying hydrostatic motors for all winches of the cableway. Position and speed control is being performed for each winding drum. Pressure limiting is also required for each hydrostatic circuit. Although overpressure valves are present in hydrostatic circuits, pressure controller is necessary for adjustable pressure limiting during the cableway operation. There is a cascade control scheme with a parallel pressure controller. The pressure control of cableway drives is a key problem described in this paper.
Název v anglickém jazyce
A Control System for Mobile Forestry Cableway with Hydrostatic Drives: Winding Drums Control
Popis výsledku anglicky
The paper deals with wood logging problems and technology. The main part is focused on control of winding drums hydrostatic drives in forestry cableway. The cableway system description is introduced in another contribution. Proportionally controlled hydrostatic pumps are used for supplying hydrostatic motors for all winches of the cableway. Position and speed control is being performed for each winding drum. Pressure limiting is also required for each hydrostatic circuit. Although overpressure valves are present in hydrostatic circuits, pressure controller is necessary for adjustable pressure limiting during the cableway operation. There is a cascade control scheme with a parallel pressure controller. The pressure control of cableway drives is a key problem described in this paper.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED0014%2F01%2F01" target="_blank" >ED0014/01/01: Centrum výzkumu a využití obnovitelných zdrojů energie</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Annals of DAAAM for 2011 & Proceedings of the 22nd International DAAAM Symposium
ISBN
978-3-901509-83-4
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
1413-1414
Název nakladatele
DAAAM International
Místo vydání
Vienna, AT
Místo konání akce
Vienna
Datum konání akce
23. 11. 2011
Typ akce podle státní příslušnosti
WRD - Celosvětová akce