Heat distribution in the photovoltaic module monitored by thermovision
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F12%3APU101348" target="_blank" >RIV/00216305:26220/12:PU101348 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Heat distribution in the photovoltaic module monitored by thermovision
Popis výsledku v původním jazyce
This paper deals with the long time monitoring of the photovoltaic module in situ by the thermovision camera. The focus of the measurement was to monitor and compare the heat distribution and the defects distribution in the module via the work in real conditions. The measurement was taken every week at the same time and the conditions of measuring were noted. The output results were recalculated to the relative value to be possible to make correlation of degradation rate and heat distribution. Once perweek at the same time, the thermovision pictures were taken of the photovoltaic module connected to the stable load and also the ambient temperature, light intensity and notes of weather conditions were taken. The efficiency of solar module was measuredonce per month and the correlation of heat distribution was made.
Název v anglickém jazyce
Heat distribution in the photovoltaic module monitored by thermovision
Popis výsledku anglicky
This paper deals with the long time monitoring of the photovoltaic module in situ by the thermovision camera. The focus of the measurement was to monitor and compare the heat distribution and the defects distribution in the module via the work in real conditions. The measurement was taken every week at the same time and the conditions of measuring were noted. The output results were recalculated to the relative value to be possible to make correlation of degradation rate and heat distribution. Once perweek at the same time, the thermovision pictures were taken of the photovoltaic module connected to the stable load and also the ambient temperature, light intensity and notes of weather conditions were taken. The efficiency of solar module was measuredonce per month and the correlation of heat distribution was made.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED0014%2F01%2F01" target="_blank" >ED0014/01/01: Centrum výzkumu a využití obnovitelných zdrojů energie</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
ALER 2011
ISBN
978-80-89456-08-6
ISSN
—
e-ISSN
—
Počet stran výsledku
7
Strana od-do
41-47
Název nakladatele
UNIZA
Místo vydání
Liptovský Mikuláš
Místo konání akce
Liptovský Ján
Datum konání akce
27. 10. 2010
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—