The Measurement of Diffusion in Plants Tissue Culture
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F12%3APU97787" target="_blank" >RIV/00216305:26220/12:PU97787 - isvavai.cz</a>
Výsledek na webu
<a href="http://piers.org/piersproceedings/download.php?file=cGllcnMyMDEyS3VhbGFMdW1wdXJ8MVA4XzA0MzgucGRmfDExMDkyMDA2NTIwMQ==" target="_blank" >http://piers.org/piersproceedings/download.php?file=cGllcnMyMDEyS3VhbGFMdW1wdXJ8MVA4XzA0MzgucGRmfDExMDkyMDA2NTIwMQ==</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Measurement of Diffusion in Plants Tissue Culture
Popis výsledku v původním jazyce
For monitoring of tissue structures of Euphorbia plants is used magnetic resonance imaging (MRI). In contrast with CT the MRI does not emit any harmful radiation. The images are obtained without any deformation or destruction of the plant. The principleof MRI techniqueis based on the measurement of the interaction of the electromagnetic waves with nuclei placed in the strong magnetic fields. Diffusion is random translational motion of molecules from a place of higher concentration to a location with lower concentrations, arising due to their thermal energy. The diffusion coeffcients measured by MRI method are describing the degrees of mobility of nuclei. Measurements of these coeffcients is performed by measuring the PFGSE sequence, it is a normal spin-echo sequence extended by two identical rectangular diffusion gradients. During measurements there are distinguished three time intervals. In the first interval the nuclei are dephased, in the next interval the nuclei diffuse (relaxatio
Název v anglickém jazyce
The Measurement of Diffusion in Plants Tissue Culture
Popis výsledku anglicky
For monitoring of tissue structures of Euphorbia plants is used magnetic resonance imaging (MRI). In contrast with CT the MRI does not emit any harmful radiation. The images are obtained without any deformation or destruction of the plant. The principleof MRI techniqueis based on the measurement of the interaction of the electromagnetic waves with nuclei placed in the strong magnetic fields. Diffusion is random translational motion of molecules from a place of higher concentration to a location with lower concentrations, arising due to their thermal energy. The diffusion coeffcients measured by MRI method are describing the degrees of mobility of nuclei. Measurements of these coeffcients is performed by measuring the PFGSE sequence, it is a normal spin-echo sequence extended by two identical rectangular diffusion gradients. During measurements there are distinguished three time intervals. In the first interval the nuclei are dephased, in the next interval the nuclei diffuse (relaxatio
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP102%2F11%2F0318" target="_blank" >GAP102/11/0318: Analýza metabolizmu a lokalizace změn kostní tkáně čelisti pomocí MR zobrazovacích technik</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Progress in Electromagnetics Research Symposium Proceedings, KL, Malaysia
ISBN
978-1-934142-12-7
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
438-441
Název nakladatele
Neuveden
Místo vydání
Kuala Lumpur
Místo konání akce
Kuala Lumpur
Datum konání akce
27. 3. 2012
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—