Detection of Skull Trauma Using Resistance Tomography
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F12%3APU97803" target="_blank" >RIV/00216305:26220/12:PU97803 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Detection of Skull Trauma Using Resistance Tomography
Popis výsledku v původním jazyce
In the article, the non-invasive way for images reconstruction of an internal conductivity distribution of the human head tissue is described. This approach is based on the use of the current density distribution obtained from measurements of external magnetic flux density by using magnetic field measurement with the principles of conventional EIT imaging technique. The proposed algorithm enables the detection of biological tissue changes in a head with a high spatial resolution. The algorithm was applied to the several computer simulations representing the detection of skull trauma to demonstrate its feasibility, and to assess the performance of reconstruction process in estimation head tissue conductivity values. The obtained results were presented and compared with the images of conductivity distribution reconstructed by the EIT algorithm. All reconstruction process properties were also discussed.
Název v anglickém jazyce
Detection of Skull Trauma Using Resistance Tomography
Popis výsledku anglicky
In the article, the non-invasive way for images reconstruction of an internal conductivity distribution of the human head tissue is described. This approach is based on the use of the current density distribution obtained from measurements of external magnetic flux density by using magnetic field measurement with the principles of conventional EIT imaging technique. The proposed algorithm enables the detection of biological tissue changes in a head with a high spatial resolution. The algorithm was applied to the several computer simulations representing the detection of skull trauma to demonstrate its feasibility, and to assess the performance of reconstruction process in estimation head tissue conductivity values. The obtained results were presented and compared with the images of conductivity distribution reconstructed by the EIT algorithm. All reconstruction process properties were also discussed.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA102%2F09%2F0314" target="_blank" >GA102/09/0314: Studium vlastností metamateriálů a mikrovlnných struktur s využitím šumové spektroskopie a magnetické rezonance</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
PIERS 2012 Kuala Lumpur Proceedings
ISBN
978-1-934142-20-2
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
390-393
Název nakladatele
Neuveden
Místo vydání
Cambridge
Místo konání akce
Kuala Lumpur
Datum konání akce
27. 3. 2012
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—