Analysis of simultaneous EEG and fMRI data
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F12%3APU98364" target="_blank" >RIV/00216305:26220/12:PU98364 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analysis of simultaneous EEG and fMRI data
Popis výsledku v původním jazyce
Neurologist are looking for connections between simultaneous EEG and fMRI data, trying to take advantages of both methods. EEG gives them a very good time resolution of the neuronal activity, while a great spatial resolution is provided by the MRI scanner, when the BOLD signal is measured. The analysis of fMRI images is mostly evaluated by the computer program Statistical Parametric Mapping (SPM). The EEG regressor builder is a software which was created in this study. It loads, processes and joins together parameters of simultaneous EEG and fMRI data into the analysis of the SPM. The second part of the study compares results from published analyses with the results calculated by the EEG regressor builder.
Název v anglickém jazyce
Analysis of simultaneous EEG and fMRI data
Popis výsledku anglicky
Neurologist are looking for connections between simultaneous EEG and fMRI data, trying to take advantages of both methods. EEG gives them a very good time resolution of the neuronal activity, while a great spatial resolution is provided by the MRI scanner, when the BOLD signal is measured. The analysis of fMRI images is mostly evaluated by the computer program Statistical Parametric Mapping (SPM). The EEG regressor builder is a software which was created in this study. It loads, processes and joins together parameters of simultaneous EEG and fMRI data into the analysis of the SPM. The second part of the study compares results from published analyses with the results calculated by the EEG regressor builder.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JD - Využití počítačů, robotika a její aplikace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP304%2F11%2F1318" target="_blank" >GAP304/11/1318: Optimalizace metodiky analýzy a hodnocení simultánního EEG-fMRI u pacientů s farmakorezistentní epilepsií</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
The proceedings of the 18th conference EEICT 2012
ISBN
978-80-214-4462-1
ISSN
—
e-ISSN
—
Počet stran výsledku
3
Strana od-do
67-69
Název nakladatele
BUT
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
26. 4. 2012
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—