Comparison of Methods of Piezoelectric Coefficient Measurement
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F12%3APU98535" target="_blank" >RIV/00216305:26220/12:PU98535 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of Methods of Piezoelectric Coefficient Measurement
Popis výsledku v původním jazyce
The paper compares the main methods used for measuring of the piezoelectric material constants. It outlines the principle of three measuring methods most commonly used today, i.e. the frequency method, the laser interferometry method and the quasi-staticmethod. These methods have been practically applied to piezoelectric ceramic samples. The paper describes the production of the piezoelectric ceramic samples of defined sizes in accordance with the current regulations. An NCE51 production code soft ceramic was used in the experiments. A piezoelectric charge coefficient was measured. The final values of the piezoelectric charge coefficient obtained through all the methods were compared to the catalogue values of the piezoelectric ceramic. All three methods can be described as appropriate; compared with the frequency method, the laser interferometry and quasi-static methods are rather time-consuming and more demanding with respect to preparation of the measurement experiment. The frequen
Název v anglickém jazyce
Comparison of Methods of Piezoelectric Coefficient Measurement
Popis výsledku anglicky
The paper compares the main methods used for measuring of the piezoelectric material constants. It outlines the principle of three measuring methods most commonly used today, i.e. the frequency method, the laser interferometry method and the quasi-staticmethod. These methods have been practically applied to piezoelectric ceramic samples. The paper describes the production of the piezoelectric ceramic samples of defined sizes in accordance with the current regulations. An NCE51 production code soft ceramic was used in the experiments. A piezoelectric charge coefficient was measured. The final values of the piezoelectric charge coefficient obtained through all the methods were compared to the catalogue values of the piezoelectric ceramic. All three methods can be described as appropriate; compared with the frequency method, the laser interferometry and quasi-static methods are rather time-consuming and more demanding with respect to preparation of the measurement experiment. The frequen
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2012 IEEE International Instrumentation and Measurement Technology Conference (I2MTC 2012) Proceedings
ISBN
978-1-4577-1771-0
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
37-42
Název nakladatele
IEEE Service Center
Místo vydání
445 Hoes Lane Piscataway, NJ 08855-1331 USA
Místo konání akce
Graz
Datum konání akce
13. 5. 2012
Typ akce podle státní příslušnosti
CST - Celostátní akce