Measurement of Particle Size Distribution by the Use of Acoustic Emission Method
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F12%3APU98929" target="_blank" >RIV/00216305:26220/12:PU98929 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measurement of Particle Size Distribution by the Use of Acoustic Emission Method
Popis výsledku v původním jazyce
This article deals with solid particle flow measurement by the use of acoustic emission method (AE). The particle impacts a waveguide and generates impulse AE. AE signal is usually measured by a piezoelectric wide-band sensor. The article expands formerly performed measurements that were focused on a research of a relationship between input particle parameters and measured frequency spectrum of AE signal. On basics obvious theoretical presumption, it is possible to obtain information about particle sizedistribution from measured signal by statistical analysis. Practical experiments were designed to prove these theoretical presumptions. In case that all the defined conditions will be fulfilled, this method could be used in practice as a simplificationof measurement of particle size distribution.
Název v anglickém jazyce
Measurement of Particle Size Distribution by the Use of Acoustic Emission Method
Popis výsledku anglicky
This article deals with solid particle flow measurement by the use of acoustic emission method (AE). The particle impacts a waveguide and generates impulse AE. AE signal is usually measured by a piezoelectric wide-band sensor. The article expands formerly performed measurements that were focused on a research of a relationship between input particle parameters and measured frequency spectrum of AE signal. On basics obvious theoretical presumption, it is possible to obtain information about particle sizedistribution from measured signal by statistical analysis. Practical experiments were designed to prove these theoretical presumptions. In case that all the defined conditions will be fulfilled, this method could be used in practice as a simplificationof measurement of particle size distribution.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2012 IEEE International Instrumentation and Measurement Technology Conference (I2MTC 2012) Proceedings
ISBN
978-1-4577-1771-0
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
1194-1198
Název nakladatele
IEEE Service Center
Místo vydání
445 Hoes Lane Piscataway, NJ 08855-1331 USA
Místo konání akce
Graz
Datum konání akce
13. 5. 2012
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—