This paper is focused on the failure monitoring in cementitious composites under mechanical loading. The aim was to determine how the cracks generation intensity depends on the aggregate size in tested concrete samples. Our diagnostic method is based onthe measurement of electromagnetic and acoustic emission signals, which occur when the solid dielectric materials are mechanically stressed. Several groups of concrete samples with various concrete composition formulas have been prepared for our experiment. We made two channel measurements of the concrete samples from each groups for defined loading conditions. This contribution describes our measurement system and also includes the pilot experimental results of the different cementitious specimens during linearly increasing uniaxial compression. From the obtained results can be concluded that the generated cracks intensity is significantly affected by the aggregate amount and size.
Název v anglickém jazyce
Use of Electromagnetic and Acoustic Emission in Failure Monitoring of Cementitious Composites
Popis výsledku anglicky
This paper is focused on the failure monitoring in cementitious composites under mechanical loading. The aim was to determine how the cracks generation intensity depends on the aggregate size in tested concrete samples. Our diagnostic method is based onthe measurement of electromagnetic and acoustic emission signals, which occur when the solid dielectric materials are mechanically stressed. Several groups of concrete samples with various concrete composition formulas have been prepared for our experiment. We made two channel measurements of the concrete samples from each groups for defined loading conditions. This contribution describes our measurement system and also includes the pilot experimental results of the different cementitious specimens during linearly increasing uniaxial compression. From the obtained results can be concluded that the generated cracks intensity is significantly affected by the aggregate amount and size.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BM - Fyzika pevných látek a magnetismus
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Fracture Mechanics for Durability, Reliability and Safety
ISBN
978-80-214-3692-3
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
530-537
Název nakladatele
Neuveden
Místo vydání
Kazaň
Místo konání akce
Kazaň
Datum konání akce
26. 8. 2012
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—