Acoustic emission localization in thin multi-layer plates using first-arrival determination
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F13%3APU103315" target="_blank" >RIV/00216305:26220/13:PU103315 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.ymssp.2012.11.008" target="_blank" >http://dx.doi.org/10.1016/j.ymssp.2012.11.008</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.ymssp.2012.11.008" target="_blank" >10.1016/j.ymssp.2012.11.008</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Acoustic emission localization in thin multi-layer plates using first-arrival determination
Popis výsledku v původním jazyce
In the case of thin plates, there exist two modes of propagation which travel at different velocities and exhibit dispersion characteristics. Techniques that are based on Gabor wavelet transform or cross-correlation technique are commonly used to locateacoustic emission (AE) events which occur in large plates. Due to side-edge reflections and short source-to-sensor distances, these techniques are not suitable for small plate-like specimens. If the thickness of the plate-like specimen is smaller than aspecific value, the first-coming (extensional) mode will show non-dispersive behavior in AE frequency range. Under such a condition, the conventional localization method can be used for detecting first-arrival times on non-dispersive extensional mode. Inprevious paper, authors of the paper developed a first-arrival automatic determination technique based on Akaike information criterion (AIC) for thin metal plates. This paper compares this technique with another AIC approach, STA/LTA met
Název v anglickém jazyce
Acoustic emission localization in thin multi-layer plates using first-arrival determination
Popis výsledku anglicky
In the case of thin plates, there exist two modes of propagation which travel at different velocities and exhibit dispersion characteristics. Techniques that are based on Gabor wavelet transform or cross-correlation technique are commonly used to locateacoustic emission (AE) events which occur in large plates. Due to side-edge reflections and short source-to-sensor distances, these techniques are not suitable for small plate-like specimens. If the thickness of the plate-like specimen is smaller than aspecific value, the first-coming (extensional) mode will show non-dispersive behavior in AE frequency range. Under such a condition, the conventional localization method can be used for detecting first-arrival times on non-dispersive extensional mode. Inprevious paper, authors of the paper developed a first-arrival automatic determination technique based on Akaike information criterion (AIC) for thin metal plates. This paper compares this technique with another AIC approach, STA/LTA met
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BM - Fyzika pevných látek a magnetismus
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
MECHANICAL SYSTEMS AND SIGNAL PROCESSING
ISSN
0888-3270
e-ISSN
—
Svazek periodika
36
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
14
Strana od-do
636-649
Kód UT WoS článku
000319302100025