This contribution introduces a new system for foot arch 3D scanning. The aim of this scanning is mainly automatic arch deformity detection and treatment efficiency evaluation in comparison among alternative therapeutic methods. Common arch deformities, which should be scaled and measured by the proposed method, are well known pes planus and pes cavus. Contemporary methods of their detection and description are based on plantogram analysis. Platogram is a poorly defined method of arch orthogonal projection to transversal plane, which could be influenced by the technical equipment used. Also the accuracy of its analysis could be affected by the method used and experience of the evaluator. Our method is based on 3D medial arch scanning by phase shift profilometry method utilization. Sets of periodical patterns are projected to the foot and captured by camera. Images are then segmented and continuous surface of the skin is mapped in space. On the basis of this depth map and colour image, a
Název v anglickém jazyce
3D Scanning Method for Foot Medial Arch Description
Popis výsledku anglicky
This contribution introduces a new system for foot arch 3D scanning. The aim of this scanning is mainly automatic arch deformity detection and treatment efficiency evaluation in comparison among alternative therapeutic methods. Common arch deformities, which should be scaled and measured by the proposed method, are well known pes planus and pes cavus. Contemporary methods of their detection and description are based on plantogram analysis. Platogram is a poorly defined method of arch orthogonal projection to transversal plane, which could be influenced by the technical equipment used. Also the accuracy of its analysis could be affected by the method used and experience of the evaluator. Our method is based on 3D medial arch scanning by phase shift profilometry method utilization. Sets of periodical patterns are projected to the foot and captured by camera. Images are then segmented and continuous surface of the skin is mapped in space. On the basis of this depth map and colour image, a
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Microwave and Radio Electronics Week MAREW 2013
ISBN
978-1-4673-5517-9
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
245-248
Název nakladatele
Neuveden
Místo vydání
Pardubice
Místo konání akce
Pardubice
Datum konání akce
16. 4. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000326877900044