A FPGA-PC Based Acoustic Emission System with Logarithmic Preamplifier for Fracture Monitoring
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F13%3APU104465" target="_blank" >RIV/00216305:26220/13:PU104465 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A FPGA-PC Based Acoustic Emission System with Logarithmic Preamplifier for Fracture Monitoring
Popis výsledku v původním jazyce
FPGAs are widely used for their versatility and speed. Their advantage lies in the parallel processing of instructions in a program in FPGA. The circuit of FPGA in combination with logarithmic a preamplifier is able to quickly process the measured data and send them to the PC for the further processing (storage, graph). The paper describes our developed compact AE system with a logarithmic preamplifier for fracture monitoring. The system is based on Field Programmable Gate Array (FPGA), which recalculates digitized logarithmic signal to linear scale and provides elementary identification of AE events and their AE features.
Název v anglickém jazyce
A FPGA-PC Based Acoustic Emission System with Logarithmic Preamplifier for Fracture Monitoring
Popis výsledku anglicky
FPGAs are widely used for their versatility and speed. Their advantage lies in the parallel processing of instructions in a program in FPGA. The circuit of FPGA in combination with logarithmic a preamplifier is able to quickly process the measured data and send them to the PC for the further processing (storage, graph). The paper describes our developed compact AE system with a logarithmic preamplifier for fracture monitoring. The system is based on Field Programmable Gate Array (FPGA), which recalculates digitized logarithmic signal to linear scale and provides elementary identification of AE events and their AE features.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/7AMB13PL032" target="_blank" >7AMB13PL032: Optimalizace detekce plynů u rezistivních senzorů a křemených mikrovážek na základě stochastických procesů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů