Thermal Conductivity and Heat Capacity of Biological Tissues Thermal Conductivity and Heat Capacity of Biological Tissues Thermal Conductivity and Heat Capacity of Biological Tissues Thermal Conductivity and Heat Capacity of Biological Tissues
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F13%3APU105626" target="_blank" >RIV/00216305:26220/13:PU105626 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Thermal Conductivity and Heat Capacity of Biological Tissues Thermal Conductivity and Heat Capacity of Biological Tissues Thermal Conductivity and Heat Capacity of Biological Tissues Thermal Conductivity and Heat Capacity of Biological Tissues
Popis výsledku v původním jazyce
This paper deals with a measurement of temperature dependencies of thermal properties only by one measure system. Specific heat and thermal conductivity are two general thermal properties subscribed here. Thermal properties of each matter are dependent on their own temperature and are various in whole temperature range. Temperature dependencies of many commercial materials are well known. But temperature dependencies of biological tissues are very bad to find. However knowledge of these parameters is very important for the thermal processes computer simulation. .The methodology described here is based on deficiencies of current measuring devices and methods. The thermal conductivity of biological tissues is measured with special needle (very thin and quite long) called the needle probe. This method has some good known deficiencies which are described in this paper. Specific heat is measured with Differential Scanning Calorimetry (DSC). The DSC is conventional method without serious deficiencies. Big disadvantage of current thermal properties measurement is in necessary using of both methods, i.e. two devices must be used. Methodology described here is based on simultaneous measurement of thermal conductivity and specific heat. It is the main advantage of our methodology. Measure system was tested only for measuring of thermal conductivity of 1 % agar and for one steady state temperature. Next part of research will be focused on specific heat measurement and temperature dependencies of both physical quantities contained here. Results of temperature dependencies measurement will be used in computer simulation for hypothermia cancer destroying.
Název v anglickém jazyce
Thermal Conductivity and Heat Capacity of Biological Tissues Thermal Conductivity and Heat Capacity of Biological Tissues Thermal Conductivity and Heat Capacity of Biological Tissues Thermal Conductivity and Heat Capacity of Biological Tissues
Popis výsledku anglicky
This paper deals with a measurement of temperature dependencies of thermal properties only by one measure system. Specific heat and thermal conductivity are two general thermal properties subscribed here. Thermal properties of each matter are dependent on their own temperature and are various in whole temperature range. Temperature dependencies of many commercial materials are well known. But temperature dependencies of biological tissues are very bad to find. However knowledge of these parameters is very important for the thermal processes computer simulation. .The methodology described here is based on deficiencies of current measuring devices and methods. The thermal conductivity of biological tissues is measured with special needle (very thin and quite long) called the needle probe. This method has some good known deficiencies which are described in this paper. Specific heat is measured with Differential Scanning Calorimetry (DSC). The DSC is conventional method without serious deficiencies. Big disadvantage of current thermal properties measurement is in necessary using of both methods, i.e. two devices must be used. Methodology described here is based on simultaneous measurement of thermal conductivity and specific heat. It is the main advantage of our methodology. Measure system was tested only for measuring of thermal conductivity of 1 % agar and for one steady state temperature. Next part of research will be focused on specific heat measurement and temperature dependencies of both physical quantities contained here. Results of temperature dependencies measurement will be used in computer simulation for hypothermia cancer destroying.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
The Electromagnetics Academy PIERS 2013
ISBN
978-1-934142-20-2
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
1681-1683
Název nakladatele
PIERS
Místo vydání
Neuveden
Místo konání akce
Stockholm
Datum konání akce
12. 8. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce