The paper deals with the theoretically derived sensitivities of the torque, resp. the current characteristics to individual substituting circuit parameters of the induction machine. It is considerably difficult to find the coincidence between the measured and calculated torque characteristics, resp. current characteristics of the induction machine. It is caused by the implementation of several simplifying assumptions during the derivation of the torque, resp. the current characteristics. All of substituting circuit parameters are considered as constants when deriving both characteristics. However, those assumptions don not meet with the real machine behavior. Particularly, skin-effect and temperature rise during measurement cause change of resistors values. Those changes afterwards lead to inaccuracy of characteristics comparison.
Název v anglickém jazyce
Sensitivity analysis of the induction machine substituting circuit
Popis výsledku anglicky
The paper deals with the theoretically derived sensitivities of the torque, resp. the current characteristics to individual substituting circuit parameters of the induction machine. It is considerably difficult to find the coincidence between the measured and calculated torque characteristics, resp. current characteristics of the induction machine. It is caused by the implementation of several simplifying assumptions during the derivation of the torque, resp. the current characteristics. All of substituting circuit parameters are considered as constants when deriving both characteristics. However, those assumptions don not meet with the real machine behavior. Particularly, skin-effect and temperature rise during measurement cause change of resistors values. Those changes afterwards lead to inaccuracy of characteristics comparison.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED0014%2F01%2F01" target="_blank" >ED0014/01/01: Centrum výzkumu a využití obnovitelných zdrojů energie</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
ELECTROMOTION
ISSN
1223-057X
e-ISSN
—
Svazek periodika
20
Číslo periodika v rámci svazku
1-4
Stát vydavatele periodika
RO - Rumunsko
Počet stran výsledku
5
Strana od-do
122-126
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—