Statistical analysis of subjective tests results of the various 3D displays
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F13%3APU105852" target="_blank" >RIV/00216305:26220/13:PU105852 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Statistical analysis of subjective tests results of the various 3D displays
Popis výsledku v původním jazyce
This article deals with the subjective evaluation of the 3D image's quality depending on the different viewing angles. Results of the subjective tests of three different 3D video-sequences and three 3D photographs made by 28 observers are shown. Subjective tests were realized on three types of 3D imaging systems: two types needing of glasses (active controlled fader glasses and passive polarized glasses) and one auto-stereoscopic display (glasses-free). The results demonstrate the expected constraints of the used imaging 3D systems. The article contains a description of the subjective tests procedure, their summary and evaluation of results. The results of the subjective tests are complemented as well by the results of the objective measurement of photometric and colorimetric parameters of all used 3D displays.
Název v anglickém jazyce
Statistical analysis of subjective tests results of the various 3D displays
Popis výsledku anglicky
This article deals with the subjective evaluation of the 3D image's quality depending on the different viewing angles. Results of the subjective tests of three different 3D video-sequences and three 3D photographs made by 28 observers are shown. Subjective tests were realized on three types of 3D imaging systems: two types needing of glasses (active controlled fader glasses and passive polarized glasses) and one auto-stereoscopic display (glasses-free). The results demonstrate the expected constraints of the used imaging 3D systems. The article contains a description of the subjective tests procedure, their summary and evaluation of results. The results of the subjective tests are complemented as well by the results of the objective measurement of photometric and colorimetric parameters of all used 3D displays.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Slaboproudý obzor
ISSN
0037-668X
e-ISSN
—
Svazek periodika
69
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
7
Strana od-do
9-15
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—