Cu2O based electrochemical sensor for direct glucose detection
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F13%3APU105912" target="_blank" >RIV/00216305:26220/13:PU105912 - isvavai.cz</a>
Výsledek na webu
<a href="http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6688515" target="_blank" >http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6688515</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/ICSENS.2013.6688515" target="_blank" >10.1109/ICSENS.2013.6688515</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Cu2O based electrochemical sensor for direct glucose detection
Popis výsledku v původním jazyce
Two types of working electrodes of electrochemical sensors were fabricated using screen-printing and spray-coating deposition methods and previously synthetized Cu2O micro/nanoparticles and used for direct electrochemical glucose detection. Glucose was successfully electrochemically detected against conventional Ag/AgCl reference electrode and platinum auxiliary electrode at potential of 0.5 V and 0.75 V for spray coated and screen printed electrode, respectively. Better sensitivity was observed using spray-coated electrode. For both electrodes types we obtained linear calibration curve in physiological range of concentrations from 0.5 to 10 mmol/L. Furthermore, the limit of detection lower than 100 umol/L was achieved.
Název v anglickém jazyce
Cu2O based electrochemical sensor for direct glucose detection
Popis výsledku anglicky
Two types of working electrodes of electrochemical sensors were fabricated using screen-printing and spray-coating deposition methods and previously synthetized Cu2O micro/nanoparticles and used for direct electrochemical glucose detection. Glucose was successfully electrochemically detected against conventional Ag/AgCl reference electrode and platinum auxiliary electrode at potential of 0.5 V and 0.75 V for spray coated and screen printed electrode, respectively. Better sensitivity was observed using spray-coated electrode. For both electrodes types we obtained linear calibration curve in physiological range of concentrations from 0.5 to 10 mmol/L. Furthermore, the limit of detection lower than 100 umol/L was achieved.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IEEE SENSORS 2013 Proceedings
ISBN
978-1-4673-4642-9
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
1534-1537
Název nakladatele
IEEE
Místo vydání
Baltimore, USA
Místo konání akce
Baltimore
Datum konání akce
3. 11. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—