Array of self-ordered Au QDs with tunable size (in the range of 10–30 nm) were successfully achieved via template based method. These QDs were composed of expected chemical elements with commonly occurring surface impurities such as carbon and oxygen. The fluorescence properties of Au QDs were found in the visible range of spectra with maximum position at about 370 nm and FWHM parameter of about 65 nm. The intensity of fluorescence significantly increased after adsorption of GSH molecules on Au QDs surface. This functionalization procedure enables further Au QDs array usage in biosensing, because GSH can serve as binding partner for detected analyte in the solution.
Název v anglickém jazyce
SELF-ORDERED GOLD QUANTUM DOTS ARRAY FOR IN VITRO BIOSENSING
Popis výsledku anglicky
Array of self-ordered Au QDs with tunable size (in the range of 10–30 nm) were successfully achieved via template based method. These QDs were composed of expected chemical elements with commonly occurring surface impurities such as carbon and oxygen. The fluorescence properties of Au QDs were found in the visible range of spectra with maximum position at about 370 nm and FWHM parameter of about 65 nm. The intensity of fluorescence significantly increased after adsorption of GSH molecules on Au QDs surface. This functionalization procedure enables further Au QDs array usage in biosensing, because GSH can serve as binding partner for detected analyte in the solution.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CE - Biochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP102%2F11%2F1068" target="_blank" >GAP102/11/1068: Nano-elektro-bio-nástroje pro biochemické a molekulárně-biologické studie eukaryotických buněk (NanoBioTECell)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Conference Proceedings 5th International Conference Nanocon 2013
ISBN
978-80-87294-44-4
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
1-6
Název nakladatele
Tanger, Ltd.
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
16. 10. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—