Detection of low-level electromagnetic signal of partial discharge by means of disturbed acquisition discrimination
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F14%3APU108965" target="_blank" >RIV/00216305:26220/14:PU108965 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Detection of low-level electromagnetic signal of partial discharge by means of disturbed acquisition discrimination
Popis výsledku v původním jazyce
The proposed article will present a new approach to detection of very weak electromagnetic signal, which is generated by partial discharge (PD). This approach is a part of radiofrequency method, known as ultra-high frequency (UHF) method. The UHF method is utilized for detection, activity quantization and localization of PD in high-voltage power transformers. The UHF method is the most advancing method for this type of transformer diagnostic. The state of the art in instrument technology allows real-time acquisition and processing of pulsed broad band signals together with 3D localization of PD occurrence. The UHF method is based on measurements of electromagnetic waves in UHF spectrum produced by PD. Typical spectrum of the PD UHF signal ranges from hundreds of MHz to units of GHz. The UHF signal is detected by sensing heads that enter the transformer through its casing. Sensing heads, which were developed at Brno University of Technology (BUT), contains antennas and a set of high-frequency components, which adapt the signals from the antennas. The signals from the sensing heads are processed by a digitizer and real-time evaluated by a custom-made software developed at BUT also. The measurement of PD activity has been made on eight power transformers in the Dukovany nuclear power plant in the Czech Republic. The initial experimental measurement, which was under full working arrangements, has been accompanied by some issues. The recorded signals contained strong interference. It has been estimated that the source of the interference is probably situated in the high voltage bushings, which feed the transformer from a turbo-generator. The interfering signal in form of electromagnetic waves has propagated through the air vicinity and it has coupled to the sensing heads. It has been found that the proper shielding is a crucial factor, while the PD signal level is far below the level of the interference. An improved shielding has been developed and it has significantly r
Název v anglickém jazyce
Detection of low-level electromagnetic signal of partial discharge by means of disturbed acquisition discrimination
Popis výsledku anglicky
The proposed article will present a new approach to detection of very weak electromagnetic signal, which is generated by partial discharge (PD). This approach is a part of radiofrequency method, known as ultra-high frequency (UHF) method. The UHF method is utilized for detection, activity quantization and localization of PD in high-voltage power transformers. The UHF method is the most advancing method for this type of transformer diagnostic. The state of the art in instrument technology allows real-time acquisition and processing of pulsed broad band signals together with 3D localization of PD occurrence. The UHF method is based on measurements of electromagnetic waves in UHF spectrum produced by PD. Typical spectrum of the PD UHF signal ranges from hundreds of MHz to units of GHz. The UHF signal is detected by sensing heads that enter the transformer through its casing. Sensing heads, which were developed at Brno University of Technology (BUT), contains antennas and a set of high-frequency components, which adapt the signals from the antennas. The signals from the sensing heads are processed by a digitizer and real-time evaluated by a custom-made software developed at BUT also. The measurement of PD activity has been made on eight power transformers in the Dukovany nuclear power plant in the Czech Republic. The initial experimental measurement, which was under full working arrangements, has been accompanied by some issues. The recorded signals contained strong interference. It has been estimated that the source of the interference is probably situated in the high voltage bushings, which feed the transformer from a turbo-generator. The interfering signal in form of electromagnetic waves has propagated through the air vicinity and it has coupled to the sensing heads. It has been found that the proper shielding is a crucial factor, while the PD signal level is far below the level of the interference. An improved shielding has been developed and it has significantly r
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Progress in Electromagnetics Research Symposium 2014, Guangzhou
ISBN
978-1-934142-28-8
ISSN
1559-9450
e-ISSN
—
Počet stran výsledku
4
Strana od-do
213-216
Název nakladatele
Neuveden
Místo vydání
Neuveden
Místo konání akce
Guangzhou
Datum konání akce
25. 8. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000393225900042