The main parameters displayed by means of magnetic resonance include, for example, relaxation times T1 and T2 or diffusion parameters. This paper presents the computation of relaxation time T2 measured indirectly with the Spin Echo method. The sensing coil of the tomograph provides a signal in which the important factor is the location of the peaks from individual measurements. These points must be interleaved with an exponential function. The relaxation time T2 can be directly determined from the exponential shape. The described process has to be repeated for each pixel of the sensed tissue, and this requirement makes the processing of larger images very demanding in terms of both the actual computation and the time needed for the entire operation. More concretely, if we assume the common resolution of 256x256, 20 slices, and five measurements with different times TE, it is necessary to reconstruct 1.3x106 exponential functions in total, which requires the processing of more than 6 MB
Název v anglickém jazyce
Fast Calculation of T2 Relaxation Time in Magnetic Resonance Imaging
Popis výsledku anglicky
The main parameters displayed by means of magnetic resonance include, for example, relaxation times T1 and T2 or diffusion parameters. This paper presents the computation of relaxation time T2 measured indirectly with the Spin Echo method. The sensing coil of the tomograph provides a signal in which the important factor is the location of the peaks from individual measurements. These points must be interleaved with an exponential function. The relaxation time T2 can be directly determined from the exponential shape. The described process has to be repeated for each pixel of the sensed tissue, and this requirement makes the processing of larger images very demanding in terms of both the actual computation and the time needed for the entire operation. More concretely, if we assume the common resolution of 256x256, 20 slices, and five measurements with different times TE, it is necessary to reconstruct 1.3x106 exponential functions in total, which requires the processing of more than 6 MB
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of PIERS 2014 in Guangzhou
ISBN
978-1-934142-28-8
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
2331-2335
Název nakladatele
Neuveden
Místo vydání
Guangzhou, Čína
Místo konání akce
Guangzhou
Datum konání akce
25. 8. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—