Time synchronized low-voltage measurements for Smart Grids
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F14%3APU111530" target="_blank" >RIV/00216305:26220/14:PU111530 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S1877705815005354" target="_blank" >https://www.sciencedirect.com/science/article/pii/S1877705815005354</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.proeng.2015.01.508" target="_blank" >10.1016/j.proeng.2015.01.508</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Time synchronized low-voltage measurements for Smart Grids
Popis výsledku v původním jazyce
This paper deals with possible future development of Smart Grids based on more detailed monitoring of grid. The aim of this work is to propose measurements for low-voltage level of Smart Grids inspired by measurements known from high-voltage level. Using time synchronization and intelligent endpoint devices creates wide area measuring grids to collect essential data for faster detection of illegal consumers, branch overload detection, power-quality verification, and other features. These can improve overall stability and reliability of grid by covering low-voltage level that is typical with dynamic change of topology, different sources of disturbances and as primary source for majority of customers.
Název v anglickém jazyce
Time synchronized low-voltage measurements for Smart Grids
Popis výsledku anglicky
This paper deals with possible future development of Smart Grids based on more detailed monitoring of grid. The aim of this work is to propose measurements for low-voltage level of Smart Grids inspired by measurements known from high-voltage level. Using time synchronization and intelligent endpoint devices creates wide area measuring grids to collect essential data for faster detection of illegal consumers, branch overload detection, power-quality verification, and other features. These can improve overall stability and reliability of grid by covering low-voltage level that is typical with dynamic change of topology, different sources of disturbances and as primary source for majority of customers.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
25th DAAAM International Symposium
ISBN
978-3-901509-99-5
ISSN
1877-7058
e-ISSN
—
Počet stran výsledku
7
Strana od-do
1389-1395
Název nakladatele
DAAAM International Vienna
Místo vydání
Vienna
Místo konání akce
Vienna
Datum konání akce
26. 11. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000380551900174