A rejuvenation process of a very old nickel-iron accumulator (about 75 years) is described in this article. The supposed nominal parameters of the accumulator are 12V/(8Ah -10Ah). All cells of the accumulator were cleaned and rejuvenated by a quite long and laborious process including 11 cycles of charging and discharging, several changing of the electrolyte and even using a deep discharging to improve the capacity of the negative iron electrode. The charging and discharging characteristics of all cells were measured during the rejuvenation. Finally also the internal resistance of the accumulator was measured. The wooden case, output terminals and all the accumulator accessories were renovated. The work showed a surprising durability of old NiFe accumulators (see below).
Název v anglickém jazyce
Rejuvenation of a NiFe Accumulator from 1930´s
Popis výsledku anglicky
A rejuvenation process of a very old nickel-iron accumulator (about 75 years) is described in this article. The supposed nominal parameters of the accumulator are 12V/(8Ah -10Ah). All cells of the accumulator were cleaned and rejuvenated by a quite long and laborious process including 11 cycles of charging and discharging, several changing of the electrolyte and even using a deep discharging to improve the capacity of the negative iron electrode. The charging and discharging characteristics of all cells were measured during the rejuvenation. Finally also the internal resistance of the accumulator was measured. The wooden case, output terminals and all the accumulator accessories were renovated. The work showed a surprising durability of old NiFe accumulators (see below).
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1210" target="_blank" >LO1210: Energie v podmínkách udržitelného rozvoje (EN-PUR)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
ECS Transactions
ISSN
1938-5862
e-ISSN
1938-6737
Svazek periodika
63
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
6
Strana od-do
167-172
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-84920586845